The Test Set,electrosurgical Apparat, cataloged under National Stock Number 6515-01-438-2409, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Fluke Electronics Corp. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: SE.
| Parameter | Value |
|---|---|
| NSN | 6515-01-438-2409 |
| Primary Part Number | 454A |
| Item Name | Test Set,electrosurgical Apparat |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Fluke Electronics Corp |
| Status | ACTIVE |
| General Characteristics Item Description | NOTE: REQUISITIONER MUST STATE VOLTAGE REQUIREMENTS WHEN ORDERING. 115 OR 230 VAC, 50 OR 60 HZ VAC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | SE |
| Part Number | Manufacturer |
|---|---|
| 454A PRIMARY | Fluke Electronics Corp (USA) |
NSN 6515-01-438-2409 is a Test Set,electrosurgical Apparat, manufactured by Fluke Electronics Corp, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-438-2409 has 1 manufacturer part number on file: 454A (Fluke Electronics Corp).
Key specifications for 454A: General Characteristics Item Description: NOTE: REQUISITIONER MUST STATE VOLTAGE REQUIREMENTS WHEN ORDERING. 115 OR 230 VAC, 50 OR 60 HZ VAC; Special Features: 115/230V, 50-60HZ, 700 WATTS; THE TEST SET IS USED TO PERFORM AUTOMATED TESTING OF ELECTROSURGICAL UNITS FOR OUTPUT POWER, CURRENT, CREST FACTOR, PEAK-TO-PEAK VOLTAGE, ACTIVE OR DISPERSIVE ELECTRODE WITH EITHER OPENED OR CLOSED LOAD CIRCUIT, RETURN FAULT MONITOR, RETURN ELECTRODE MONITOR, ASPEN RETURN MONITOR,AND EXTENDED LOAD RANGES. THE UNIT HAS A MINIMUM: 24 USER-DEFINABLE AUTOSEQUENCES, EACH CAPABLE OF 50 INDIVIDUAL CHECKS AT A DESIRED TEST LOAD, POWER LEVEL, DIAL SETTING, AND ELECTRODE CONFIGURATION; 32 USER-SELECTABLE ISOLATED TEST LOADS; MANUAL, USER-PROGRAMMABLE, AND REMOTE (VIA RS 232C) MODES OF TESTING AND PRINTING OPERATION; 0.2 VOLTS/AMPS UNCALIBRATED OSCILLOSCOPE OUTPUT; 200 OHMS AT 12 WATTS MAXIMUM RF LEAKAGE TEST LOAD RANGE, 3 AUXILIARY MODULES; PATIENT RETURN CONTACT MONITOR/FAULT TEST MODULE, 25 OHM BIPOLAR EXPANSION MODULE, AND 2000 OHM MONOPOLAR EXPANSION MODULAR. COMES W/HARD SIDE CARRYING CASE;2 COPIES OPERATOR/SERVICE MANUAL, 3 LEAD TEST SET V; Part Name Assigned by Controlling Agency: TEST SET ELECTROSURGICAL APPARATUS 115/230 V 50/60 HZ V. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.