PartsTable TECHNICAL DATA SHEET
NSN 6515-01-435-4305Government record, cited

Anesthesia Apparatus, Field6515-01-435-4305

NSN 6515-01-435-4305 · NIIN 014354305
FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment
Government record, cited
Also searched as  6515-01-435-4305 · 6515014354305 · NIIN 014354305 · 01-435-4305 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies
Nearby stock numbers  ·
Features
  • Anesthesia Apparatus,field — FSC 6515
  • Accessory Components and Quantity: REUSABLE MASK: 1 ADULT, 1 PEDIATRIC, AND 1 INFANT. REUSABLE BREATHING CIRCUIT: 1 ADULT AND 1 PEDIATRIC. USER MANUALS, 2 EA.; MAINTENANCE MANUAL, 2 EA. REUABLE CONTAINER: 1 EA.
Identification
  • NSN: 6515-01-435-4305
  • NIIN: 014354305
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
General Description

The Anesthesia Apparatus,field, cataloged under National Stock Number 6515-01-435-4305, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-435-4305
Item NameAnesthesia Apparatus,field
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
StatusACTIVE
Accessory Components and QuantityREUSABLE MASK: 1 ADULT, 1 PEDIATRIC, AND 1 INFANT. REUSABLE BREATHING CIRCUIT: 1 ADULT AND 1 PEDIATRIC. USER MANUALS, 2 EA.; MAINTENANCE MANUAL, 2 EA. REUABLE CONTAINER: 1 EA.
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6515-01-561-2850960-525 POSSIBLE MATCH
BIOPSY NEEDLE,IG
Possible match (shared part number)Medtronics Xomed Surgical Products Inc Dba Medtronics Xomed
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
96-0525 3/2 Design control — primary reference
U.S. Government activity
Related Parts
6515-01-561-2850POSSIBLE MATCH
BIOPSY NEEDLE,IG
960-525

Frequently Asked Questions

What is NSN 6515-01-435-4305?

NSN 6515-01-435-4305 is a Anesthesia Apparatus,field, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What NSN replaces 6515-01-435-4305?

1 possible match (shared part number, not a government interchangeability claim): 6515-01-561-2850. Verify interchangeability with system specifications before substitution.

What are the specifications of 6515-01-435-4305?

Key specifications for 6515-01-435-4305: Accessory Components and Quantity: REUSABLE MASK: 1 ADULT, 1 PEDIATRIC, AND 1 INFANT. REUSABLE BREATHING CIRCUIT: 1 ADULT AND 1 PEDIATRIC. USER MANUALS, 2 EA.; MAINTENANCE MANUAL, 2 EA. REUABLE CONTAINER: 1 EA.; Special Features: A PORTABLE FIELD ANESTHESIA MACHINE (FAM), PERMITTING USE OF CLOSED (LOW FLOW), SEMI-CLOSED AND OPENED ANESTHESIA TECHNIQUES. 110/220 VAC, 50/60 HZ. WITH BATTERY BACKUP TO FULLY POWER ALL OPERATIONS FOR A MINIMUM OF ONE HOUR. THE UNIT C/O: A CARBON DIOXIDE (CO2) ABSORBER, OXYGEN (O2) ABSORBER, VENTILATOR, AND VAPORIZER. HAS NITROUS OXIDE CAPABILITY AND HAS A OPERATIONAL RANGE OF 40-61 PSI. ACCEPTS AN OXYGEN CONCENTRATOR (WHEN AVAILABLE), AIR COMPRESSOR, OXYGEN CYLINDERS, PIPELINE OXYGEN, NITROUS OXIDE, AND OTHER AIR SOURCES. UNIT IS ADAPTABLE TO USE BOTH ACTIVE AND PASSIVE GAS SCAVENGING SYSTEMS AND IS SUPPLIED WITH GAS PRESSURES GUAGES, BREAK-RESISTANT FLOWMETERS, AND AN OXYGEN FLUSH VALVE. MONITORING CAPABILITIES: FRACTION OF INSPIRED OXYGEN (FIO2), PEAK AIRWAY PRESSURE (PAW),AND EXHALED VOLUME. THE VAPORIZER HAS A MIN. CAP. OF 100 ML AND THE VENTILATOR HAS A FLOW RATE OF 0-50 LPM. THE UNIT IS STERILIZABLE IAW WITH DEPMEDS PROCEDURES. VAC; Part Name Assigned by Controlling Agency: ANESTHESIA APPARATUS FIELD:. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-435-4305 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com