The Catheter,cardiovascular, cataloged under National Stock Number 6515-01-392-4155, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Edwards Lifesciences Corp Div Edwards Research Medical. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-392-4155 |
| Primary Part Number | 746HF8 |
| Item Name | Catheter,cardiovascular |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Edwards Lifesciences Corp Div Edwards Research Medical |
| Status | ACTIVE |
| Style Designator | THERMODILUTION |
| Catheter Nominal Length | 110.0 CENTIMETERS CM |
| Nominal Diameter | 8.000 FRENCH |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 746HF8 PRIMARY | Edwards Lifesciences Corp Div Edwards Research Medical (USA) |
| Reference | Meaning |
|---|---|
| 746H-8F | 3/9 Design control — primary reference Baxter Healthcare Corp Edwards Critical Care Div |
| 94-4-12-49-LT | 5/1 Secondary reference U.S. Government activity |
NSN 6515-01-392-4155 is a Catheter,cardiovascular, manufactured by Edwards Lifesciences Corp Div Edwards Research Medical, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-392-4155 has 1 manufacturer part number on file: 746HF8 (Edwards Lifesciences Corp Div Edwards Research Medical).
Key specifications for 746HF8: Style Designator: THERMODILUTION; Catheter Nominal Length: 110.0 CENTIMETERS CM; Nominal Diameter: 8.000 FRENCH; Special Features: SWAN-GANZ DESIGNED; C/O THERMAL FLAMENT CONNECTOR; THERMISTOR CONNECTOR; BALLOON INFLATION VALVE; OPTICAL MODULE CONNECTOR; PA DISTAL LUMAN HUB; VIP LUMAN HUB; PROXIMAL INJECTION LUMEN HUB;; TERMISTOR 4CM; BALLOON; THERMAL FLAMENT; PA. DISTAL LUMEN; VIP PORT 30CM; PROXIMAL INJECTION PORT 28 CM; DESIGNED TO CONTINUOUSLY MONITOR BOTH CARDIAC OUTPUT AND MIXED VENOUS CM. 3 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.