The Recorder System,defibrillator-Mo, cataloged under National Stock Number 6515-01-389-6740, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 2 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-389-6740 |
| Item Name | Recorder System,defibrillator-Mo |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Status | ACTIVE |
| Supplementary Features | AEROMEDICALLY CERTIFIED FOR FIXED WING AND ROTARY AIRCRAFT; JOINT AIRWORTHINESS CERTIFICATION (JAC) |
| Furnished Items | REUSABLE PADDED CARRYING/STORAGE CASE, 1 EA; ECG CABLE, 1 EA; DEFIB PADDLES, 2 EA (1 PEDIATRIC AND 1 ADULT); MONITORING ELECTRODES, 24 SETS; PACING ELECTRODES, 10 SETS; DEFIBRILLATOR CONDUCTIVE PADS, 3 SETS; NICAD BATTERY, 4 EA; RECORDER PAPER, 6 ROLLS; APPLICABLE POWER CABLES, AND OPERATOR/SERVICE MANUAL, 2 EA. |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Reference | Meaning |
|---|---|
| 9-0426 | 3/2 Design control — primary reference U.S. Government activity |
| 94-6054 | 5/1 Secondary reference U.S. Government activity |
NSN 6515-01-389-6740 is a Recorder System,defibrillator-Mo, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
Key specifications for 6515-01-389-6740: Supplementary Features: AEROMEDICALLY CERTIFIED FOR FIXED WING AND ROTARY AIRCRAFT; JOINT AIRWORTHINESS CERTIFICATION (JAC); Special Features: WITH PACING; PORTABLE; BOTH LINE AND BATTERY POWERED; AUXILLARY POWER SUPPLY 110 VAC, 50 HZ; BATTERY CHARGER SUPPLY 110/220 VAC, 50/60 HZ; DUAL VOLTAGE RATED; C/O: NON-INVASIVE PACEMAKER, DEFIBRILLATOR, ECG MONITOR, RECORDER, AND EXTERNAL BATTERY CHARGER; UNIT IS IMPACT RESISTANT AND OPERABLE IN WET ENVIRONMENTS; THE RECORDER SHALL ANNOTATE AT A MINIMUM: TIME, DATE, HEART RATE, PACER PARAMETERS, DEFIBRILLATOR PARAMETERS, GAIN AND LEAD; SHALL HAVE SIX (6) ADJUSTABLE DISCRETE ENERGY STEPS INCLUDING, BUT NOT LIMITED TO, 10, 50, 100, 200, 300 AND 360 JOULES; EXTERNAL PACEMAKER SHALL HAVE NON-INVASIVE CARDIAC PACING RATES FROM 40 THROUGH 150 BEATS/MINUTE; USES DISPOSABLE, PRE-GELLED ELECTRODES; DEMAND PACEMAKER CAPABLE OF ASYNCHRONOUS OPERATION; DELIVERED OUTPUT CURRENT IS CONTINUOUSLY ADJUSTABLE OVER THE RANGE OF 0-200 MILLIAMPS VAC; Furnished Items: REUSABLE PADDED CARRYING/STORAGE CASE, 1 EA; ECG CABLE, 1 EA; DEFIB PADDLES, 2 EA (1 PEDIATRIC AND 1 ADULT); MONITORING ELECTRODES, 24 SETS; PACING ELECTRODES, 10 SETS; DEFIBRILLATOR CONDUCTIVE PADS, 3 SETS; NICAD BATTERY, 4 EA; RECORDER PAPER, 6 ROLLS; APPLICABLE POWER CABLES, AND OPERATOR/SERVICE MANUAL, 2 EA.; Part Name Assigned by Controlling Agency: DEFIBRILLATOR MONITOR RECORDER: 120/230V 50/60HZ AC OR DC V. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.