The Handle,electrode,electrosurgery, cataloged under National Stock Number 6515-01-388-1102, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Ethicon Ltd (a Johnson & Johnson Company). Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: PG.
| Parameter | Value |
|---|---|
| NSN | 6515-01-388-1102 |
| Primary Part Number | EPH01 |
| Item Name | Handle,electrode,electrosurgery |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Ethicon Ltd (a Johnson & Johnson Company) |
| Status | ACTIVE |
| Style Designator | ELECTRODE-ELECTRO-SURGERY |
| Features Provided | PISTOL GRIP |
| Material | UNABLE TO DECODE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | PG |
| Part Number | Manufacturer |
|---|---|
| EPH01 | Ethicon Ltd (a Johnson & Johnson Company) (GBR) |
| EPH01 | Johnson and Johnson Professional Products (GBR) |
| Reference | Meaning |
|---|---|
| F94B007 | 5/1 Secondary reference Air Force Medical Logistics Office |
| 94-2-25-54 DE | 5/1 Secondary reference Air Force Medical Logistics Office |
| EPH01 | 3/9 Design control — primary reference Ethicon, Inc |
NSN 6515-01-388-1102 is a Handle,electrode,electrosurgery, manufactured by Ethicon Ltd (a Johnson & Johnson Company), classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-388-1102 has 2 manufacturer part numbers on file: EPH01 (Ethicon Ltd (a Johnson & Johnson Company)), EPH01 (Johnson and Johnson Professional Products).
Key specifications for EPH01: Style Designator: ELECTRODE-ELECTRO-SURGERY; Features Provided: PISTOL GRIP; Special Features: FOOT CONTROL ELECTROSURGERY PISTOL GRIP HANDLE; PART OF ELCTROSURGERY PROBE PLUS II SYSTEM; HOLDS AND MANIPULATES ELECTRODES FOR CUTTING, DEHYDRATIANG AND DESTROYING TISSUE; UNIT QTY 6; Part Name Assigned by Controlling Agency: HANDLE ELECTRODE ELECTROSURGERY H17 STYLE PLASTIC FOOT CONTROL6S. 3 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.