The Oxygenator,blood, cataloged under National Stock Number 6515-01-384-4024, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cobe Laboratories Inc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-384-4024 |
| Primary Part Number | 050-212-000 |
| Item Name | Oxygenator,blood |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Cobe Laboratories Inc |
| Status | ACTIVE |
| Component and Quantity | OPTIMA OPEN SYSTEM OXYGENATOR WITH INTEGRAL CARDIOTOMY FILTER ; INTEGRAL CARDIOTOMY FILTER |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 050-212-000 PRIMARY | Cobe Laboratories Inc (USA) |
NSN 6515-01-384-4024 is a Oxygenator,blood, manufactured by Cobe Laboratories Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-384-4024 has 1 manufacturer part number on file: 050-212-000 (Cobe Laboratories Inc).
Key specifications for 050-212-000: Component and Quantity: OPTIMA OPEN SYSTEM OXYGENATOR WITH INTEGRAL CARDIOTOMY FILTER ; INTEGRAL CARDIOTOMY FILTER; Special Features: STERILE; NON-PYROGENIC; DISPOSABLE; SINGLE USE ONLY; PRIMING VOLUME 260 ML; BLOOD FLOW RANGE 0.5-8 LITERS/MIN; HEIGHT 5.5 IN (14 CM); WIDTH 5 IN (12.7 CM); LENGTH 10.1 IN (25.7 CM); WEIGHT 1.75 LBS (800 G); STAINLESS STEEL HEAT EXCHANGER, SURFACE AREA 213 IN SQUARED (1374 CM SQUARED), WATERSIDE PRESSURE RATING, 60 PSI (423 KG/CM SQUARED); MEMBRANE, HOLLOW FIBER (BLOOD OUTSIDE FIBER) MEMBRANE CONFIGURATION, SURFACE AREA 1.7 M SQUARED, MICROPOROUS POLYPROPYLENE MATERIAL; PORTS: OXYGENATOR INLET (3/8 IN (9.5 MM)), OXYGENATOR OUTLET (3/8 IN (9.5 MM), ARTERIAL BLOOD ACCESS (1/4 IN (6.4 MM), ARTERIAL SAMPLING (FEMALE LUER LOCK); FITTINGS: GAS INLET (1/4 IN (6.4 MM)), WATER INLET & OUTLET (HANSEN 3ST), ARTERIAL TEMPERATURE PROBE (YSI SERIES 400), ANESTHETIC GAS SCAVENGE (3/8 IN (9.5 MM); 2/CASE LBS. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.