The Catheter,jejunal, cataloged under National Stock Number 6515-01-382-4541, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is C. R. Bard, Inc.. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-382-4541 |
| Primary Part Number | 4251 |
| Item Name | Catheter,jejunal |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | C. R. Bard, Inc. |
| Status | ACTIVE |
| Style Designator | JEJUNOSTOMY W/BALLOON |
| Catheter Nominal Length | 0.108 INCHES IN |
| Tip Type | BLUNT |
| Core Fabrication Method | NOT WOVEN |
| Patient Size Designation | ADULT |
| Nominal Diameter | 16.000 FRENCH |
| Material | PLASTIC OVERALL |
| Balloon Capacity | 15.0 CUBIC CENTIMETERS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 4251 PRIMARY | C. R. Bard, Inc. (USA) |
| Reference | Meaning |
|---|---|
| F93I066 | 5/1 Secondary reference Air Force Medical Logistics Office |
| 93-9-17-115 FS | 5/1 Secondary reference Air Force Medical Logistics Office |
NSN 6515-01-382-4541 is a Catheter,jejunal, manufactured by C. R. Bard, Inc., classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-382-4541 has 1 manufacturer part number on file: 4251 (C. R. Bard, Inc.).
Key specifications for 4251: Style Designator: JEJUNOSTOMY W/BALLOON; Catheter Nominal Length: 0.108 INCHES IN; Tip Type: BLUNT; Core Fabrication Method: NOT WOVEN. 8 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.