The Needle,amniocentesis, cataloged under National Stock Number 6515-01-346-0151, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Vance Products Inc Dba Cook Urological. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-346-0151 |
| Primary Part Number | KDAN-221001 |
| Item Name | Needle,amniocentesis |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Vance Products Inc Dba Cook Urological |
| Status | ACTIVE |
| Needle Cannula Gage Designation and Location | 22 GAGE INNER NEEDLE |
| Unit Package Quantity | 1 |
| Material | STEEL CORROSION RESISTING OVERALL |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| KDAN-221001 PRIMARY | Vance Products Inc Dba Cook Urological (USA) |
| Reference | Meaning |
|---|---|
| 91-5-21-262 LST | 5/1 Secondary reference Air Force Medical Logistics Office |
| F91E166 | 5/1 Secondary reference Air Force Medical Logistics Office |
NSN 6515-01-346-0151 is a Needle,amniocentesis, manufactured by Vance Products Inc Dba Cook Urological, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-346-0151 has 1 manufacturer part number on file: KDAN-221001 (Vance Products Inc Dba Cook Urological).
Key specifications for KDAN-221001: Needle Cannula Gage Designation and Location: 22 GAGE INNER NEEDLE; Unit Package Quantity: 1; Special Features: ECHO TIP; SIDE HOLES; DESIGNED TO BE USED IN TRANS-ABDOMINAL PREFORATION OF THE UTERUS TO PERMIT DRAINAGE OF THE ANIOTIC FLUID DURING OBSTETRIC AND GYNECOLOGY PROCEDURES; Part Name Assigned by Controlling Agency: NEEDLE AMNIOCENTESIS 22 GAGE INNER NEEDLE ECHO TIP SIDE HOLES DISP. 3 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.