The Catheter,intravenous, cataloged under National Stock Number 6515-01-312-2950, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Teleflex Llc. Government technical data includes 10 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: PG.
| Parameter | Value |
|---|---|
| NSN | 6515-01-312-2950 |
| Primary Part Number | IV-01100 |
| Item Name | Catheter,intravenous |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Teleflex Llc |
| Status | ACTIVE |
| Style Designator | INTRAVENOUS INJECTION |
| Design Designation | INTRAVENOUS |
| Unit Package Quantity | 25 |
| Tip Type | BLUNT AND OPEN END |
| Core Fabrication Method | NOT WOVEN |
| Connector Type | LUER LOCK HUB |
| Patient Size Designation | ADULT |
| Nominal Diameter | 18.000 GAGE |
| Material | STEEL CORROSION RESISTING NEEDLE |
| Material | PLASTIC POLYURETHANE CATHETER |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | PG |
| Part Number | Manufacturer |
|---|---|
| IV-01100 PRIMARY | Teleflex Llc (USA) |
| Reference | Meaning |
|---|---|
| IV-01100 | 3/9 Design control — primary reference Arrow International, Inc. Dba Teleflex |
| 89-9- 29-109 MSP | 5/1 Secondary reference Department of the Army U S Army Medical Material Agency Mcmr-Mmo-Sa |
| A89I055 | 5/1 Secondary reference Department of the Army U S Army Medical Material Agency Mcmr-Mmo-Sa |
NSN 6515-01-312-2950 is a Catheter,intravenous, manufactured by Teleflex Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-312-2950 has 1 manufacturer part number on file: IV-01100 (Teleflex Llc).
Key specifications for IV-01100: Style Designator: INTRAVENOUS INJECTION; Design Designation: INTRAVENOUS; Unit Package Quantity: 25; Tip Type: BLUNT AND OPEN END. 10 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.