PartsTable TECHNICAL DATA SHEET
NSN 6515-01-280-1865Government record, cited

Screw, Bone6515-01-280-1865

NSN 6515-01-280-1865 · NIIN 012801865 · Part number 47-1154-024-00
Zimmer, Inc. Dba Z Hotel · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 67239
Government record, cited
NSN 6515-01-280-1865 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-280-1865. Manufacturer of record part number: 47-1154-024-00.
Also searched as  6515-01-280-1865 · 6515012801865 · NIIN 012801865 · 01-280-1865 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 67239 · 47-1154-024-00 · 1154-24 · 88-4-18-86 MSP
Nearby stock numbers  ·
Features
  • Screw,bone — FSC 6515
  • Length: 24.0 MILLIMETERS NOMINAL MM
  • Material: STEEL CORROSION RESISTING OVERALL
  • 1 manufacturer part number on file
  • Manufacturer of record: Zimmer, Inc. Dba Z Hotel
Identification
  • NSN: 6515-01-280-1865
  • NIIN: 012801865
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 47-1154-024-00
  • Manufacturer: Zimmer, Inc. Dba Z Hotel
General Description

The Screw,bone, cataloged under National Stock Number 6515-01-280-1865, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Zimmer, Inc. Dba Z Hotel. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-280-1865
Primary Part Number47-1154-024-00
Item NameScrew,bone
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerZimmer, Inc. Dba Z Hotel
StatusACTIVE
Length24.0 MILLIMETERS NOMINAL MM
MaterialSTEEL CORROSION RESISTING OVERALL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
47-1154-024-00 PRIMARY Zimmer, Inc. Dba Z Hotel (USA)
Reference documents
ReferenceMeaning
1154-24 5/9 Secondary reference
Zimmer, Inc. Dba Z Hotel
88-4-18-86 MSP 5/1 Secondary reference
Air Force Medical Logistics Office
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-280-1865?

NSN 6515-01-280-1865 is a Screw,bone, manufactured by Zimmer, Inc. Dba Z Hotel, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-280-1865?

NSN 6515-01-280-1865 has 1 manufacturer part number on file: 47-1154-024-00 (Zimmer, Inc. Dba Z Hotel).

What are the specifications of 47-1154-024-00?

Key specifications for 47-1154-024-00: Length: 24.0 MILLIMETERS NOMINAL MM; Special Features: 3MM; 4MM THREADED DIA; 1.85MM SHANK DIA; F/INTERFRAGMENTAL COMPRESSION OF CARPEL SCAPHOID; INTRA-ARTICULAR AND OSTEOCHONDRAL FRACTURES; ABSENCE OF PROTRUSIVE SCREW HEAD ALLOWS SCREW TO BE COMPLETELY INSERTED ACROSS FRACTURE SITE INTO BONE UNDER CORTEX; THREADS AT BOTH ENDS COMPRESSES THE TWO FRACTURE FRAGMENTS TOGETHER AND MAINTAINS RIGID INTERNAL FIXATION MM; Part Name Assigned by Controlling Agency: SCREW BONE 24MM LG 4MM THREADED DIA 1.85MM SHANK DIA CRS MM; Material: STEEL CORROSION RESISTING OVERALL. 2 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-280-1865 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com