PartsTable TECHNICAL DATA SHEET
NSN 6515-01-279-9928Government record, cited

Driver, Wire, Orthopedic6515-01-279-9928

NSN 6515-01-279-9928 · NIIN 012799928 · Part number 5053-13
Linvatec Corporation Div Linvatec · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 15904
Government record, cited
NSN 6515-01-279-9928 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-279-9928. Manufacturer of record part number: 5053-13.
Also searched as  6515-01-279-9928 · 6515012799928 · NIIN 012799928 · 01-279-9928 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 15904 · 5053-13 · DPD 158
Nearby stock numbers  ·
Features
  • Driver,wire,orthopedic — FSC 6515
  • Design Designation: KIRSCHNER
  • 1 manufacturer part number on file
  • Manufacturer of record: Linvatec Corporation Div Linvatec
Identification
  • NSN: 6515-01-279-9928
  • NIIN: 012799928
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 5053-13
  • Manufacturer: Linvatec Corporation Div Linvatec
General Description

The Driver,wire,orthopedic, cataloged under National Stock Number 6515-01-279-9928, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Linvatec Corporation Div Linvatec. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-279-9928
Primary Part Number5053-13
Item NameDriver,wire,orthopedic
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerLinvatec Corporation Div Linvatec
StatusACTIVE
Design DesignationKIRSCHNER
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
5053-13 PRIMARY Linvatec Corporation Div Linvatec (USA)
Reference documents
ReferenceMeaning
DPD 158 5/1 Secondary reference
Dept of Defence (casg)land Systems Division
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-279-9928?

NSN 6515-01-279-9928 is a Driver,wire,orthopedic, manufactured by Linvatec Corporation Div Linvatec, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-279-9928?

NSN 6515-01-279-9928 has 1 manufacturer part number on file: 5053-13 (Linvatec Corporation Div Linvatec).

What are the specifications of 5053-13?

Key specifications for 5053-13: Design Designation: KIRSCHNER; Special Features: AIR POWERED; LIGHTWEIGHT; 0-1100 RPM AT 160 PSI; FRICTION MECHANISM HOLDS WIRE IN INSTRUMENT; ACCOMMODATES WIRES UP TO 9 INCH LONG,PLAIN OR THREADED FROM 0.028 TO 0.62 INCH DIA; FOR USE WITH HOSE,NITROGEN-COMPRESSED AIR; 6515-01-267-6115 IN ORTHOPEDIC PROCEDURES IN; Part Name Assigned by Controlling Agency: DRIVER WIRE ORTHO KIRSCHNER DSGN 0-1100 RPM AT 160 PSI AIR PWR RPM. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-279-9928 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com