PartsTable TECHNICAL DATA SHEET
NSN 6515-01-263-5749Government record, cited

Evacuator, Surgical Wound6515-01-263-5749

NSN 6515-01-263-5749 · NIIN 012635749
FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment
Government record, cited
Also searched as  6515-01-263-5749 · 6515012635749 · NIIN 012635749 · 01-263-5749 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies
Nearby stock numbers  ·
Features
  • Evacuator,surgical Wound — FSC 6515
  • Tubing Stem Outside Diameter: 0.125 INCHES NOMINAL IN
  • Component and Quantity: SPRING TYPE PUMP,1; 6 IN. LONG NEEDLE W/THREADED END TO ACCEPT WOUND TUBING,1; RADIOPAQUE,NONTOXIC,NONPYROGENIC,1/4 IN. O.D.,1/8 IN. I.D.,48 IN. LONG WOUND TUBING,1; Y-TYPE CONNECTOR,1; AUTOMATIC RESET VALVE,1; ANTIREFLUX VALVE,1; TUBING CLAMP,1 IN
  • Material: PLASTIC TUBE
  • Material: STEEL CORROSION RESISTING NEEDLE
Identification
  • NSN: 6515-01-263-5749
  • NIIN: 012635749
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
General Description

The Evacuator,surgical Wound, cataloged under National Stock Number 6515-01-263-5749, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 4 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-263-5749
Item NameEvacuator,surgical Wound
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
StatusACTIVE
Tubing Stem Outside Diameter0.125 INCHES NOMINAL IN
Component and QuantitySPRING TYPE PUMP,1; 6 IN. LONG NEEDLE W/THREADED END TO ACCEPT WOUND TUBING,1; RADIOPAQUE,NONTOXIC,NONPYROGENIC,1/4 IN. O.D.,1/8 IN. I.D.,48 IN. LONG WOUND TUBING,1; Y-TYPE CONNECTOR,1; AUTOMATIC RESET VALVE,1; ANTIREFLUX VALVE,1; TUBING CLAMP,1 IN
MaterialPLASTIC TUBE
MaterialSTEEL CORROSION RESISTING NEEDLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
5420-28 3/9 Design control — primary reference
Depuy Orthopaedics, Inc.

Frequently Asked Questions

What is NSN 6515-01-263-5749?

NSN 6515-01-263-5749 is a Evacuator,surgical Wound, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What are the specifications of 6515-01-263-5749?

Key specifications for 6515-01-263-5749: Tubing Stem Outside Diameter: 0.125 INCHES NOMINAL IN; Component and Quantity: SPRING TYPE PUMP,1; 6 IN. LONG NEEDLE W/THREADED END TO ACCEPT WOUND TUBING,1; RADIOPAQUE,NONTOXIC,NONPYROGENIC,1/4 IN. O.D.,1/8 IN. I.D.,48 IN. LONG WOUND TUBING,1; Y-TYPE CONNECTOR,1; AUTOMATIC RESET VALVE,1; ANTIREFLUX VALVE,1; TUBING CLAMP,1 IN; Special Features: STERILE; 400 CC CAPACITY; Material: PLASTIC TUBE. 4 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-263-5749 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.