The Tube,endobronchial, cataloged under National Stock Number 6515-01-256-4939, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Icu Medical Sales, Inc.. Government technical data includes 7 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-256-4939 |
| Primary Part Number | 198-35L |
| Item Name | Tube,endobronchial |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Icu Medical Sales, Inc. |
| Status | ACTIVE |
| Style Designator | DOUBLE LUMEN DUODENAL TUBE WITH BALLOON ON DISTAL TIP |
| Design Designation | LEFT MAINSTEM BRONCHUS |
| Tip Type | BEVELED |
| Inflation Device | PILOT BALLOON |
| Core Fabrication Method | NOT WOVEN |
| Nominal Diameter | 35.000 FRENCH |
| Material | PLASTIC POLYVINYL CHLORIDE (PVC) TUBE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| KC5-16035 | Cardinal Health 200, Llc (USA) |
| 198-35L PRIMARY | Icu Medical Sales, Inc. (USA) |
| Reference | Meaning |
|---|---|
| 95892 | 3/9 Design control — primary reference Mallinckrodt Inc Ncc Div |
| 198-35L | 5/9 Secondary reference Smiths Medical Asd Inc Dba Smiths Medical Asd, Inc |
NSN 6515-01-256-4939 is a Tube,endobronchial, manufactured by Icu Medical Sales, Inc., classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-256-4939 has 2 manufacturer part numbers on file: KC5-16035 (Cardinal Health 200, Llc), 198-35L (Icu Medical Sales, Inc.).
1 possible match (shared part number, not a government interchangeability claim): 6515-01-568-0961. Verify interchangeability with system specifications before substitution.
Key specifications for 198-35L: Style Designator: DOUBLE LUMEN DUODENAL TUBE WITH BALLOON ON DISTAL TIP; Design Designation: LEFT MAINSTEM BRONCHUS; Tip Type: BEVELED; Inflation Device: PILOT BALLOON. 7 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.