PartsTable TECHNICAL DATA SHEET
NSN 6515-01-238-9937Government record, cited

Forceps, Hemostatic6515-01-238-9937

NSN 6515-01-238-9937 · NIIN 012389937 · Part number CH6233
Cardinal Health · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0TMU4
Government record, cited
NSN 6515-01-238-9937 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-238-9937. Manufacturer of record part number: CH6233.
Also searched as  6515-01-238-9937 · 6515012389937 · NIIN 012389937 · 01-238-9937 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0TMU4 · CH6233
Nearby stock numbers  ·
Features
  • Forceps,hemostatic — FSC 6515
  • Jaw Length: 30.0 MILLIMETERS NOMINAL MM
  • Design Designation: COOLEY
  • Grip Type: FINGER RING
  • Material: STEEL CORROSION RESISTING OVERALL
  • Usage Design: USED IN THORACIC/CARDIVASCULAR
  • 1 manufacturer part number on file
  • Manufacturer of record: Cardinal Health
Identification
  • NSN: 6515-01-238-9937
  • NIIN: 012389937
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: CH6233
  • Manufacturer: Cardinal Health
General Description

The Forceps,hemostatic, cataloged under National Stock Number 6515-01-238-9937, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cardinal Health. Government technical data includes 5 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-238-9937
Primary Part NumberCH6233
Item NameForceps,hemostatic
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerCardinal Health
StatusACTIVE
Jaw Length30.0 MILLIMETERS NOMINAL MM
Design DesignationCOOLEY
Grip TypeFINGER RING
MaterialSTEEL CORROSION RESISTING OVERALL
Usage DesignUSED IN THORACIC/CARDIVASCULAR
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
CH6233 PRIMARY Cardinal Health (USA)
Reference documents
ReferenceMeaning
CH6233 5/9 Secondary reference
Baxter Healthcare Corp Operating Room Div V Mueller Government Sales
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-238-9937?

NSN 6515-01-238-9937 is a Forceps,hemostatic, manufactured by Cardinal Health, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-238-9937?

NSN 6515-01-238-9937 has 1 manufacturer part number on file: CH6233 (Cardinal Health).

What are the specifications of CH6233?

Key specifications for CH6233: Overall Length: 6.500 INCHES NOMINAL IN; Jaw Length: 30.0 MILLIMETERS NOMINAL MM; Design Designation: COOLEY; Grip Type: FINGER RING. 5 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-238-9937 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com