The Implant,adhesion Prevention,otol, cataloged under National Stock Number 6515-01-206-5982, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Olympus America Inc. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-206-5982 |
| Primary Part Number | 14-0219 |
| Item Name | Implant,adhesion Prevention,otol |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Olympus America Inc |
| Status | ACTIVE |
| Material | PLASTIC OVERALL |
| Usage Design | LAID INTO THE HYPOTYMPANUM TO PREVENT ADHESIONS OF TYMPANOPLASTY GRAFTS; TO AID IN THE CREATION OF AN AIR-CONTAINING CAVUM MIRROR |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 14-0219 PRIMARY | Olympus America Inc (USA) |
| Reference | Meaning |
|---|---|
| 6515-00-L00-0736 | 3/1 Design control — primary reference U.S. Government activity |
| SCHUKNECHT TEFLON CRESCENT | 5/9 Secondary reference Gyrus Ent Llc Dba Gyrus Ent |
| 14-0219 | 5/9 Secondary reference Gyrus Ent Llc Dba Gyrus Ent |
| SCHUKNECHT TEFLON CRESCENT | 5/1 Secondary reference Olympus America Inc |
NSN 6515-01-206-5982 is a Implant,adhesion Prevention,otol, manufactured by Olympus America Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-206-5982 has 1 manufacturer part number on file: 14-0219 (Olympus America Inc).
Key specifications for 14-0219: Overall Length: 11.0 MILLIMETERS NOMINAL MM; Overall Width: 3.0 MILLIMETERS NOMINAL MM; Special Features: MAY BE TRIMMED TO ASSURE PROPER FIT; LEFT IN PLACE INDEFINITELY; Part Name Assigned by Controlling Agency: IMPLANT ADHESION PREVENTION OTOLOGICAL 11X3MM PLASTIC. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.