The Plethysmograph, cataloged under National Stock Number 6515-01-196-1713, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Physio-Control Inc Div Request New Awards Go to Ujpnln1m18b3. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-196-1713 |
| Primary Part Number | 801095 |
| Item Name | Plethysmograph |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Physio-Control Inc Div Request New Awards Go to Ujpnln1m18b3 |
| Status | ACTIVE |
| General Characteristics Item Description | A FINGER PULSE SENSOR,TO MEASURE BLOOD FLOW VOLUME CHANGES; MEASURE BLOOD PRESSURE CHANGES CAUSED BY RESPIRATION OR ABNORMAL VOLUME CHANGES CAUSED BY PARTIAL OR TOTAL VENOUS BLOCKAGE; FOR USE WITH MONITOR,VITAL SIGNS,FSCM 28494,P/NO 800570; AN 8 FOOT CABLE WITH A SIX PIN CONNECTOR AND AN ALLIGATOR CLIP ON THE PROXIMAL END; ALLIGATOR CLIP HAS A LIGHT EMITTING DIODE THAT SENSES THE AMPLITUDE,SHAPE AND DURATION OF THE WAVE FORM IN THE BLOOD AND TRANSMITS THE WAVE BACK TO THE MONITOR FT |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 801095 PRIMARY | Physio-Control Inc Div Request New Awards Go to Ujpnln1m18b3 (USA) |
NSN 6515-01-196-1713 is a Plethysmograph, manufactured by Physio-Control Inc Div Request New Awards Go to Ujpnln1m18b3, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-196-1713 has 1 manufacturer part number on file: 801095 (Physio-Control Inc Div Request New Awards Go to Ujpnln1m18b3).
1 possible match (shared part number, not a government interchangeability claim): 5998-01-292-2750. Verify interchangeability with system specifications before substitution.
Key specifications for 801095: General Characteristics Item Description: A FINGER PULSE SENSOR,TO MEASURE BLOOD FLOW VOLUME CHANGES; MEASURE BLOOD PRESSURE CHANGES CAUSED BY RESPIRATION OR ABNORMAL VOLUME CHANGES CAUSED BY PARTIAL OR TOTAL VENOUS BLOCKAGE; FOR USE WITH MONITOR,VITAL SIGNS,FSCM 28494,P/NO 800570; AN 8 FOOT CABLE WITH A SIX PIN CONNECTOR AND AN ALLIGATOR CLIP ON THE PROXIMAL END; ALLIGATOR CLIP HAS A LIGHT EMITTING DIODE THAT SENSES THE AMPLITUDE,SHAPE AND DURATION OF THE WAVE FORM IN THE BLOOD AND TRANSMITS THE WAVE BACK TO THE MONITOR FT; Part Name Assigned by Controlling Agency: PLETHYSMOGRAPH 8 FOOT CABLE WITH 6 PIN CONN AND ALLIGATOR CLIP FT. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.