PartsTable TECHNICAL DATA SHEET
NSN 6515-01-157-9671Government record, cited

Evacuator, Surgical Wound6515-01-157-9671

NSN 6515-01-157-9671 · NIIN 011579671 · Part number 5300-000-10
Snyder Laboratories Inc · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 59561
Government record, cited
NSN 6515-01-157-9671 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-157-9671. Manufacturer of record part number: 5300-000-10.
Also searched as  6515-01-157-9671 · 6515011579671 · NIIN 011579671 · 01-157-9671 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 59561 · 5300-000-10 · 5300
Nearby stock numbers  ·
Features
  • Evacuator,surgical Wound — FSC 6515
  • Tubing Stem Outside Diameter: 0.125 INCHES NOMINAL IN
  • Design Designation: SNYDER HEMOVAC
  • Component and Quantity: 6 IN. LONG NEEDLE W/THREADED END,1; BELLOWS TYPE PUMP,1; VACUUM ASSIST DEVICE,1; RADIOPAQUE,NONTOXIC,NONPYROGENIC,1/8 IN. OD,1/6 IN. ID,42 IN. LONG,WOUND TUBING W/12 IN. OF PERFORATIONS IN CENTER,1; UNIVERSAL Y CONNECTOR,1; 3/16 IN. OD,1/8 IN. ID,30 IN. LONG,EVACUATOR TUBING,1; ANTI-REFLUX VALVE,1 IN
  • Material: STEEL CORROSION RESISTING NEEDLE
  • Material: PLASTIC VINYL TUBE
  • 1 manufacturer part number on file
  • Manufacturer of record: Snyder Laboratories Inc
Identification
  • NSN: 6515-01-157-9671
  • NIIN: 011579671
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 5300-000-10
  • Manufacturer: Snyder Laboratories Inc
General Description

The Evacuator,surgical Wound, cataloged under National Stock Number 6515-01-157-9671, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Snyder Laboratories Inc. Government technical data includes 5 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-157-9671
Primary Part Number5300-000-10
Item NameEvacuator,surgical Wound
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerSnyder Laboratories Inc
StatusACTIVE
Tubing Stem Outside Diameter0.125 INCHES NOMINAL IN
Design DesignationSNYDER HEMOVAC
Component and Quantity6 IN. LONG NEEDLE W/THREADED END,1; BELLOWS TYPE PUMP,1; VACUUM ASSIST DEVICE,1; RADIOPAQUE,NONTOXIC,NONPYROGENIC,1/8 IN. OD,1/6 IN. ID,42 IN. LONG,WOUND TUBING W/12 IN. OF PERFORATIONS IN CENTER,1; UNIVERSAL Y CONNECTOR,1; 3/16 IN. OD,1/8 IN. ID,30 IN. LONG,EVACUATOR TUBING,1; ANTI-REFLUX VALVE,1 IN
MaterialSTEEL CORROSION RESISTING NEEDLE
MaterialPLASTIC VINYL TUBE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
5300-000-10 PRIMARY Snyder Laboratories Inc (USA)
Reference documents
ReferenceMeaning
5300 5/9 Secondary reference
Snyder Laboratories Inc
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-157-9671?

NSN 6515-01-157-9671 is a Evacuator,surgical Wound, manufactured by Snyder Laboratories Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-157-9671?

NSN 6515-01-157-9671 has 1 manufacturer part number on file: 5300-000-10 (Snyder Laboratories Inc).

What are the specifications of 5300-000-10?

Key specifications for 5300-000-10: Tubing Stem Outside Diameter: 0.125 INCHES NOMINAL IN; Design Designation: SNYDER HEMOVAC; Component and Quantity: 6 IN. LONG NEEDLE W/THREADED END,1; BELLOWS TYPE PUMP,1; VACUUM ASSIST DEVICE,1; RADIOPAQUE,NONTOXIC,NONPYROGENIC,1/8 IN. OD,1/6 IN. ID,42 IN. LONG,WOUND TUBING W/12 IN. OF PERFORATIONS IN CENTER,1; UNIVERSAL Y CONNECTOR,1; 3/16 IN. OD,1/8 IN. ID,30 IN. LONG,EVACUATOR TUBING,1; ANTI-REFLUX VALVE,1 IN; Special Features: STERILE; INDIVIDUALLY PACKAGED; 400 CC CAPACITY; VACUUM PUMP CHAMBER CAPABLE OF MAINTAINING AN AVERAGE VACUUM OF 70 MM OF MERCURY; UNIT QTY 10 MM. 5 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-157-9671 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com