The Drainage Unit,pleural Cavity, cataloged under National Stock Number 6515-01-140-9548, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Davol Inc. Government technical data includes 4 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 4 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-140-9548 |
| Primary Part Number | 7750 |
| Item Name | Drainage Unit,pleural Cavity |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Davol Inc |
| Status | ACTIVE |
| Quantity | 1 |
| Transparent Feature | NOT INCLUDED |
| Nonsupply Items and Quantities | PLASTIC CONTAINER,2100 CC CAPACITY,1; MILKABLE LATEX PATIENT CONNECTING TUBE,72 INCH LONG,3/8 INCH,1; SUCTION CONNECTING TUBE,1 FOOT LONG,1/4 INCH ID,1; STRAIGHT CONNECTOR,3/8 BY 3/8 INCH,1; Y CONNECTOR IN |
| Drainage Container Type | BOTTLE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 7750 PRIMARY | Davol Inc (USA) |
| Reference | Meaning |
|---|---|
| 6515-01-C15-3711 | 5/1 Secondary reference U.S. Government activity |
| THORA-KLEX CHEST DRAINAGE SET | 3/1 Design control — primary reference Davol Inc |
NSN 6515-01-140-9548 is a Drainage Unit,pleural Cavity, manufactured by Davol Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-140-9548 has 1 manufacturer part number on file: 7750 (Davol Inc).
4 possible matches (shared part number, not a government interchangeability claim): 4720-01-289-1744, 6130-01-381-6863, 5985-01-391-3466. Verify interchangeability with system specifications before substitution.
Key specifications for 7750: Quantity: 1; Transparent Feature: NOT INCLUDED; Nonsupply Items and Quantities: PLASTIC CONTAINER,2100 CC CAPACITY,1; MILKABLE LATEX PATIENT CONNECTING TUBE,72 INCH LONG,3/8 INCH,1; SUCTION CONNECTING TUBE,1 FOOT LONG,1/4 INCH ID,1; STRAIGHT CONNECTOR,3/8 BY 3/8 INCH,1; Y CONNECTOR IN; Special Features: STERILE; DISPOSABLE; GRADUATED; UNIT QTY 8. 4 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.