PartsTable TECHNICAL DATA SHEET
NSN 6515-01-140-2299Government record, cited

Forceps, Hemostatic6515-01-140-2299

NSN 6515-01-140-2299 · NIIN 011402299 · Part number CH1682
Carefusion Solutions, Llc Div Pyxis · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0YKK5
Government record, cited
NSN 6515-01-140-2299 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-140-2299. Manufacturer of record part number: CH1682.
Also searched as  6515-01-140-2299 · 6515011402299 · NIIN 011402299 · 01-140-2299 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0YKK5 · CH1682 · MDS1245124
Nearby stock numbers  ·
Features
  • Forceps,hemostatic — FSC 6515
  • Jaw Grasping Facility Arrangement: OPPOSED
  • Jaw Type: CURVED
  • Compression Retaining Method: RATCH-PAWL
  • Jaw Length: 3.000 INCHES NOMINAL IN
  • Design Designation: SAROT
  • Grip Type: FINGER RING
  • Jaw Grasping Method: SERRATED
Identification
  • NSN: 6515-01-140-2299
  • NIIN: 011402299
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: CH1682
  • Manufacturer: Carefusion Solutions, Llc Div Pyxis
General Description

The Forceps,hemostatic, cataloged under National Stock Number 6515-01-140-2299, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Carefusion Solutions, Llc Div Pyxis. Government technical data includes 9 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-140-2299
Primary Part NumberCH1682
Item NameForceps,hemostatic
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerCarefusion Solutions, Llc Div Pyxis
StatusACTIVE
Jaw Grasping Facility ArrangementOPPOSED
Jaw TypeCURVED
Compression Retaining MethodRATCH-PAWL
Jaw Length3.000 INCHES NOMINAL IN
Design DesignationSAROT
Grip TypeFINGER RING
Jaw Grasping MethodSERRATED
MaterialSTEEL CORROSION RESISTING OVERALL
Joint TypeBOX LOCK
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
CH1682 Cardinal Health 200, Llc (USA)
CH1682 PRIMARY Carefusion Solutions, Llc Div Pyxis (USA)
MDS1245124 PRIMARY Medline Industries, Lp (USA)
Reference documents
ReferenceMeaning
CH1682 3/9 Design control — primary reference
Baxter Healthcare Corp Operating Room Div V Mueller Government Sales
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-140-2299?

NSN 6515-01-140-2299 is a Forceps,hemostatic, manufactured by Carefusion Solutions, Llc Div Pyxis, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-140-2299?

NSN 6515-01-140-2299 has 3 manufacturer part numbers on file: CH1682 (Cardinal Health 200, Llc), CH1682 (Carefusion Solutions, Llc Div Pyxis), MDS1245124 (Medline Industries, Lp).

What are the specifications of CH1682?

Key specifications for CH1682: Jaw Grasping Facility Arrangement: OPPOSED; Jaw Type: CURVED; Compression Retaining Method: RATCH-PAWL; Overall Length: 9.500 INCHES NOMINAL IN. 9 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-140-2299 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com