The Nebulizer,medicinal, cataloged under National Stock Number 6515-01-074-2528, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Teleflex Llc. Government technical data includes 5 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-074-2528 |
| Primary Part Number | 1710 |
| Item Name | Nebulizer,medicinal |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Teleflex Llc |
| Status | ACTIVE |
| Nasal Tip | NOT PROVIDED |
| Disposition After Initial Use | DISPOSABLE |
| Accessory Components and Quantity | MASK, AEROSOL, ADULT, 1; TUBING, OXYGEN, 7 FOOT LENGTH, 1 FT |
| Material | PLASTIC OVERALL |
| Operation Method | COMPRESSED AIR LINE OR OXYGEN CYLINDER |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 3280001710 | Owens & Minor Distribution Inc (USA) |
| 1710 PRIMARY | Teleflex Llc (USA) |
| Reference | Meaning |
|---|---|
| 1710 | 5/9 Secondary reference Hudson Respiratory Care Inc |
| 1710 | 3/9 Design control — primary reference Teleflex Medical Incorporated Dba Teleflex Medical Inc |
| UPDRAFT | 5/9 Secondary reference Hudson Respiratory Care Inc |
NSN 6515-01-074-2528 is a Nebulizer,medicinal, manufactured by Teleflex Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-074-2528 has 2 manufacturer part numbers on file: 3280001710 (Owens & Minor Distribution Inc), 1710 (Teleflex Llc).
2 possible matches (shared part number, not a government interchangeability claim): 6515-01-076-7912, 6515-01-458-1927. Verify interchangeability with system specifications before substitution.
Key specifications for 1710: Nasal Tip: NOT PROVIDED; Disposition After Initial Use: DISPOSABLE; Accessory Components and Quantity: MASK, AEROSOL, ADULT, 1; TUBING, OXYGEN, 7 FOOT LENGTH, 1 FT; Special Features: INDIVIDUALLY PACKAGED; HAND-HELD T-DESIGN; 5 TO 15 CC CAPACITY MEDICATION CHAMBER; CONTINUOUS FLOW CONFIGURATION. 5 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.