The Electrode,electrocardiograph, cataloged under National Stock Number 6515-01-025-6043, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Conmed Corp Dba Conmed Linvatec Div Conmed Corporation. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: PG.
| Parameter | Value |
|---|---|
| NSN | 6515-01-025-6043 |
| Primary Part Number | 38-404-1 |
| Item Name | Electrode,electrocardiograph |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Conmed Corp Dba Conmed Linvatec Div Conmed Corporation |
| Status | ACTIVE |
| Accessory Components | CONNECTOR |
| Material | COPPER ALLOY OVERALL |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | PG |
| Part Number | Manufacturer |
|---|---|
| 38-404-1 PRIMARY | Conmed Corp Dba Conmed Linvatec Div Conmed Corporation (USA) |
NSN 6515-01-025-6043 is a Electrode,electrocardiograph, manufactured by Conmed Corp Dba Conmed Linvatec Div Conmed Corporation, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-025-6043 has 1 manufacturer part number on file: 38-404-1 (Conmed Corp Dba Conmed Linvatec Div Conmed Corporation).
Key specifications for 38-404-1: Special Features: FOAM; 2-1/2 IN. DIA. PAD; LEADWIRE COMBINED INTO A SINGLE CABLE CONNECTOR FOR EASY HOOK UP; PREGELLED PRESSURE SENSITIVE ADHESIVE COATED BACKING W/O,SILVER/SILVER CHLORIDE GEL; FOUR LEAD CONFIGURATION; MAY CAUSE PROLONGED RECOVERY TIME AFTER APPLICATION OF A DEFIBRILLATION PULSE; NOT SUITABLE FOR EMERGENCY ROOM USE IN; Accessory Components: CONNECTOR; Part Name Assigned by Controlling Agency: ELECTRODE EKG 2.50" DIA PREGELLED PLASTIC FOAM 4 ATCH WIRES 100S; Material: COPPER ALLOY OVERALL. 2 specifications are documented in the U.S. Government catalog.