The Refractometer,clini, cataloged under National Stock Number 6515-00-933-3218, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Reichert Inc Dba Reichert Inc. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-00-933-3218 |
| Primary Part Number | 1310400A |
| Item Name | Refractometer,clini |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Reichert Inc Dba Reichert Inc |
| Status | ACTIVE |
| Unit of Issue Cube | 0.217 CUBIC FEET |
| Universal Medical Device Nomenclature System Code | 18633 |
| General Characteristics Item Description | HAND IMMERSION TYPE,ALUMINUM,3 SCALE DIRECT READING,URINE SPECIFIC GRAVITY RANGE 1.000 TO 1.035 W/0.001 GRADUATED INTERVALS AND VALUES MARKED AT EACH 0.005 GRADUATION,SERUM OR PLASMA PROTEIN 2.500 TO 15.000 GM/100ML W/0.1GM/100ML INTERVALS AND VALUES MARKED AT EACH 0.5 GRADUATION,REFRACTIVE INDEX 0 TO 320 W/2.0 INTERVALS AND MARKED AT EVERY TENTH GRADUATION,TEMPERATURE COMPENSATED MEASURING PRISM INCORPORATED,W/RECALIBRATION FEATURE,FOCUSING EYEPIECE,CONVERSION CHART,O/A DIM. 6.375 IN. LG X 1.250 IN. DIA,PROTECTIVE CASE PROVIDED W |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 1310400A PRIMARY | Reichert Inc Dba Reichert Inc (USA) |
| Reference | Meaning |
|---|---|
| 10400A | 5/9 Secondary reference Leica Inc Surveying and Photogrammetry Systems Div |
NSN 6515-00-933-3218 is a Refractometer,clini, manufactured by Reichert Inc Dba Reichert Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-00-933-3218 has 1 manufacturer part number on file: 1310400A (Reichert Inc Dba Reichert Inc).
Key specifications for 1310400A: Unit of Issue Cube: 0.217 CUBIC FEET; Universal Medical Device Nomenclature System Code: 18633; General Characteristics Item Description: HAND IMMERSION TYPE,ALUMINUM,3 SCALE DIRECT READING,URINE SPECIFIC GRAVITY RANGE 1.000 TO 1.035 W/0.001 GRADUATED INTERVALS AND VALUES MARKED AT EACH 0.005 GRADUATION,SERUM OR PLASMA PROTEIN 2.500 TO 15.000 GM/100ML W/0.1GM/100ML INTERVALS AND VALUES MARKED AT EACH 0.5 GRADUATION,REFRACTIVE INDEX 0 TO 320 W/2.0 INTERVALS AND MARKED AT EVERY TENTH GRADUATION,TEMPERATURE COMPENSATED MEASURING PRISM INCORPORATED,W/RECALIBRATION FEATURE,FOCUSING EYEPIECE,CONVERSION CHART,O/A DIM. 6.375 IN. LG X 1.250 IN. DIA,PROTECTIVE CASE PROVIDED W; Special Features: HAND IMMERSION TYPE,ALUMINUM,3 SCALE DIRECT READING,URINE SPECIFIC GRAVITY RANGE 1.000 TO 1.035 W/0.001 GRADUATED INTERVALS AND VALUES MARKED AT EACH 0.005 GRADUATION,SERUM OR PLASMA PROTEIN 2.500 TO 15.000 GM/100ML W/0.1GM/100ML INTERVALS AND VALUES MARKED AT EACH 0.5 GRADUATION,REFRACTIVE INDEX 0 TO 320 W/2.0 INTERVALS AND MARKED AT EVERY TENTH GRADUATION,TEMPERATURE COMPENSATED MEASURING PRISM INCORPORATED,W/RECALIBRATION FEATURE,FOCUSING EYEPIECE,CONVERSION CHART,O/A DIM. 6.375 IN. LG X 1.250 IN. DIA,PROTECTIVE CASE PROVIDED W. 3 specifications are documented in the U.S. Government catalog.