The Scissors,bandage, cataloged under National Stock Number 6515-00-363-8840, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Teleflex-Ct- Devices Inc Dba Teleflex Medical. Government technical data includes 6 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 12 commercial cross-references from 11 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-00-363-8840 |
| Primary Part Number | 142420 |
| Item Name | Scissors,bandage |
| FSC / FSG | 6515 / 65 — No Item Name Available |
| Manufacturer | Teleflex-Ct- Devices Inc Dba Teleflex Medical |
| Status | ACTIVE |
| Material | STEEL CORROSION RESISTING OVERALL |
| Cut Length | 2.000 INCHES MINIMUM AND 2.219 INCHES MAXIMUM IN |
| Grip Type | FINGER RING |
| Blade Shape | ANGLE TO HANDLE |
| Design Designation | LISTER |
| Blade Point Type | ONE BLUNT AND ONE SHARP |
| Acquisition Status | ACTIVE |
| Successor | 6515-01-724-3667 (5351) |
| HAZMAT | No |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| SK11-1072 | Cardinal Health 200, Llc (USA) |
| 5-516 | Miltex Instrument Company Inc (USA) |
| 54-4013 | Specialty Surgical Instrumentation, Inc. Dba Symmetry Surgical Inc Div Symmetry Surgical (USA) |
| 535-1 | Acme Precision Surgical Inc Dba a & P Surgical Co (USA) |
| 5867111072 | Owens & Minor Distribution Inc (USA) |
| 142420 PRIMARY | Teleflex-Ct- Devices Inc Dba Teleflex Medical (USA) |
| SU2007 PRIMARY | Carefusion 2200 Inc (USA) |
| 10-2992 | Boss Instruments, Limited Inc (USA) |
| 54-4013 | Codman & Shurtleff Inc (USA) |
| 54-4013 PRIMARY | Aspen Surgical Products Inc (USA) |
| SU2007 | Cardinal Health 200, Llc (USA) |
| 11-1072 PRIMARY | Sklar Corporation Dba Sklar Instruments (USA) |
NSN 6515-00-363-8840 is a Scissors,bandage, manufactured by Teleflex-Ct- Devices Inc Dba Teleflex Medical, classified under FSC 6515 (No Item Name Available). Status: active.
NSN 6515-00-363-8840 has 12 cross-referenced part numbers: SK11-1072 (Cardinal Health 200, Llc), 5-516 (Miltex Instrument Company Inc), 54-4013 (Specialty Surgical Instrumentation, Inc. Dba Symmetry Surgical Inc Div Symmetry Surgical), 535-1 (Acme Precision Surgical Inc Dba a & P Surgical Co), 5867111072 (Owens & Minor Distribution Inc) and 7 more.
There are 12 known substitutes for 6515-00-363-8840: 6130-01-033-6995, 6515-01-724-3667, 1650-00-135-4836 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for 142420: Material: STEEL CORROSION RESISTING OVERALL; Cut Length: 2.000 INCHES MINIMUM AND 2.219 INCHES MAXIMUM IN; Part Name Assigned by Controlling Agency: BANDAGE SCISSORS; Overall Length: 7.000 INCHES MINIMUM AND 7.500 INCHES MAXIMUM IN. 9 total characteristics are documented in the Federal Logistics Information System.