The Forceps,hemostatic, cataloged under National Stock Number 6515-00-334-4300, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Bausch & Lomb Incorporated Div Surgical. Government technical data includes 8 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 9 commercial cross-references from 7 manufacturers, enabling identification through both NSN and commercial part number lookups. 7 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-00-334-4300 |
| Primary Part Number | N5541 |
| Item Name | Forceps,hemostatic |
| FSC / FSG | 6515 / 65 — No Item Name Available |
| Manufacturer | Bausch & Lomb Incorporated Div Surgical |
| Status | ACTIVE |
| Joint Type | BOX LOCK |
| Material | STEEL CORROSION RESISTING OVERALL |
| Jaw Type | QUARTER-CURVED |
| Grip Type | FINGER RING |
| Jaw Length | 1.875 INCHES NOMINAL IN |
| Jaw Grasping Method | SERRATED |
| Design Designation | ROCHESTER-PEAN |
| Compression Retaining Method | RATCH-PAWL |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| SU2760 | Carefusion 2200 Inc (USA) |
| 18-2445 | Pilling Surgical Inc Dba Pilling Weck Div Pilling Instruments (USA) |
| 14-1322 | Boss Instruments, Limited Inc (USA) |
| 324071 | Codman & Shurtleff Inc (USA) |
| SU2760 | Baxter Healthcare Corp Operating Room Div V Mueller Government Sales (USA) |
| 34-4071 | Codman & Shurtleff Inc (USA) |
| 33-4071 | Codman & Shurtleff Inc (USA) |
| SU2760 | Cardinal Health (USA) |
| N5541 PRIMARY | Bausch & Lomb Incorporated Div Surgical (USA) |
NSN 6515-00-334-4300 is a Forceps,hemostatic, manufactured by Bausch & Lomb Incorporated Div Surgical, classified under FSC 6515 (No Item Name Available). Status: active.
NSN 6515-00-334-4300 has 9 cross-referenced part numbers: SU2760 (Carefusion 2200 Inc), 18-2445 (Pilling Surgical Inc Dba Pilling Weck Div Pilling Instruments), 14-1322 (Boss Instruments, Limited Inc), 324071 (Codman & Shurtleff Inc), SU2760 (Baxter Healthcare Corp Operating Room Div V Mueller Government Sales) and 4 more.
There are 7 known substitutes for 6515-00-334-4300: 5307-00-025-8270, 1620-00-525-9594, 4820-00-566-0685 and 4 more. Verify interchangeability with system specifications before substitution.
Key specifications for N5541: Overall Length: 6.000 INCHES MINIMUM AND 6.500 INCHES MAXIMUM IN; Joint Type: BOX LOCK; Material: STEEL CORROSION RESISTING OVERALL; Jaw Type: QUARTER-CURVED. 10 total characteristics are documented in the Federal Logistics Information System.