PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

2599Evacuator,surgical Wound

Snyder Laboratories Inc · NSN 6515-00-122-0467 · FSC 6515 · No Item Name Available
Verified by PartsTable
NSN 6515-00-122-0467 — this item is cataloged by the U.S. Government under National Stock Number 6515-00-122-0467. Primary manufacturer part number: 2599.
Features
  • Evacuator,surgical Wound — FSC 6515
  • Material: PLASTIC CHAMBER
  • Chamber Shape: CYLINDRICAL
  • Chamber Top Section Shape: CIRCULAR FLAT TOP
  • Material: STEEL CORROSION RESISTING SPRING
  • Tubing Stem Outside Diameter: 0.250 INCHES NOMINAL IN
  • Chamber Catch Basin Shape: CYLINDRICAL
  • Component and Quantity: CHAMBER,1; SPRING TYPE VACUUM PUMP,1; TUBING,VACUUM PUMP,1; TUBING,WOUND,RADIOPAQUE,1; 3-WAY Y-TYPE CONNECTOR,1; ANTI-REFLUX VALVE,1
Applications
  • Applications requiring Plastic Chamber construction
General Description

The Evacuator,surgical Wound, cataloged under National Stock Number 6515-00-122-0467, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Snyder Laboratories Inc. Government technical data includes 7 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 1 commercial cross-reference from 1 manufacturer, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-00-122-0467
Primary Part Number2599
Item NameEvacuator,surgical Wound
FSC / FSG6515 / 65 — No Item Name Available
ManufacturerSnyder Laboratories Inc
StatusACTIVE
MaterialPLASTIC CHAMBER
Chamber ShapeCYLINDRICAL
Chamber Top Section ShapeCIRCULAR FLAT TOP
MaterialSTEEL CORROSION RESISTING SPRING
Tubing Stem Outside Diameter0.250 INCHES NOMINAL IN
Chamber Catch Basin ShapeCYLINDRICAL
Component and QuantityCHAMBER,1; SPRING TYPE VACUUM PUMP,1; TUBING,VACUUM PUMP,1; TUBING,WOUND,RADIOPAQUE,1; 3-WAY Y-TYPE CONNECTOR,1; ANTI-REFLUX VALVE,1
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 12
5975-00-284-8837101D INTERCHANGEABLE
Cover,junction Box
Ni Industries Inc Bowers Mfg Co Div
6625-00-442-0192 INTERCHANGEABLE
Ammeter
5815-00-603-67932599 INTERCHANGEABLE
Clutch Release Assembly
Marine Corps Systems Command Div Marine Corps Systems Command Technical Data Repository Customer Service
1560-00-650-88688-1050-2 INTERCHANGEABLE
Adapter,flanged
Parker-Hannifin Corporation Dba Pneutronics
2540-00-895-64272599 INTERCHANGEABLE
Handle,crank Lever
Dayton-Walther Corp
2940-01-049-74631046Z279 INTERCHANGEABLE
Filter Element,intake Air Cleane
Morris Material Handling, Inc.
5305-01-050-148182599 INTERCHANGEABLE
Screw,machine
Romac Industries, Inc. Dba Hays Fluid Controls Div Hays Fluid Controls Division
5910-01-096-54822599 INTERCHANGEABLE
Capacitor
Crown Audio, Inc. Dba Crown International
4820-01-122-36052599 INTERCHANGEABLE
Diaphragm,valve,flat
Imi Cash Valve Inc
5935-01-225-25433356 INTERCHANGEABLE
Adapter,connector
Cinch Connectivity Solutions Inc
Cross-Reference Index
Part NumberManufacturer
2599 PRIMARY Snyder Laboratories Inc (USA)
Related Parts
5975-00-284-8837INTERCHANGEABLE
COVER,JUNCTION BOX
101D
6625-00-442-0192INTERCHANGEABLE
AMMETER
5815-00-603-6793INTERCHANGEABLE
CLUTCH RELEASE ASSEMBLY
2599
1560-00-650-8868INTERCHANGEABLE
ADAPTER,FLANGED
8-1050-2
2540-00-895-6427INTERCHANGEABLE
HANDLE,CRANK LEVER
2599
2940-01-049-7463INTERCHANGEABLE
FILTER ELEMENT,INTAKE AIR CLEANE
1046Z279
5305-01-050-1481INTERCHANGEABLE
SCREW,MACHINE
82599
5910-01-096-5482INTERCHANGEABLE
CAPACITOR
2599
4820-01-122-3605INTERCHANGEABLE
DIAPHRAGM,VALVE,FLAT
2599
5935-01-225-2543INTERCHANGEABLE
ADAPTER,CONNECTOR
3356
6750-01-382-0484INTERCHANGEABLE
PAPER,PHOTOGRAPHIC
6060-01-420-6212INTERCHANGEABLE
SPLICE,FIBER OPTIC CONDUCTOR

Frequently Asked Questions

What is NSN 6515-00-122-0467?

NSN 6515-00-122-0467 is a Evacuator,surgical Wound, manufactured by Snyder Laboratories Inc, classified under FSC 6515 (No Item Name Available). Status: active.

What are the part numbers for NSN 6515-00-122-0467?

NSN 6515-00-122-0467 has 1 cross-referenced part number: 2599 (Snyder Laboratories Inc).

What NSN replaces 6515-00-122-0467?

There are 12 known substitutes for 6515-00-122-0467: 5975-00-284-8837, 6625-00-442-0192, 5815-00-603-6793 and 9 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 2599?

Key specifications for 2599: Material: PLASTIC CHAMBER; Chamber Shape: CYLINDRICAL; Special Features: SPRING TYPE CHAMBER (VACUUM PUMP) WITH 400 CC CAPACITY; EVACUATOR TUBE HAS 1/8 INCH I. D.,36 INCHES LONG; WOUND TUBING HAS 1/16 INCH I. D.,48 INCHES LONG,WITH 11 INCHES OF PERFORATIONS IN CENTER IN; Chamber Top Section Shape: CIRCULAR FLAT TOP. 8 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com