NSN 6515-00-104-9006 · NIIN 001049006 · Part number 334-24
Dow Silicones Corporation · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 71984
Government record, cited
NSN 6515-00-104-9006 — this item is cataloged by the U.S. Government under National Stock Number 6515-00-104-9006. Manufacturer of record part number: 334-24.
Also searched as6515-00-104-9006 ·
6515001049006 ·
NIIN 001049006 ·
00-104-9006 ·
FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 71984 · 334-24 · 266724 · 166824CE
FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
FSG: 65 — Medical, Dental, and Veterinary Equipment
Primary part number: 334-24
Manufacturer: Dow Silicones Corporation
General Description
The Catheter,urethral, cataloged under National Stock Number 6515-00-104-9006, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Dow Silicones Corporation. Government technical data includes 10 specifications, cited from the U.S. Government catalog. The record lists 4 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 7 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
Technical Specifications
Parameter
Value
NSN
6515-00-104-9006
Primary Part Number
334-24
Item Name
Catheter,urethral
FSC / FSG
6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
Manufacturer
Dow Silicones Corporation
Status
ACTIVE
Supplementary Features
D-DAY ITEM FOR DOD
Proximal End Funnel Quantity
2
Style Designator
MODIFIED RETENTION
Design Designation
FOLEY
Tip Type
ROUND
Nominal Diameter
24.000 FRENCH
Material
RUBBER OVERALL
Balloon Capacity
30.0 MILLILITERS
Shaft Eye Quantity
2
Lumen Passage Quantity
1
Lifecycle & Compliance
Acquisition Status
ACTIVE
DEMIL Code
DEMIL A — No Demilitarization Required
Hazard
No hazard code in the DLA record (HMIC N)
Criticality Code
X
⇄Related Items7
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
4310-00-883-070933424POSSIBLE MATCH
VALVE ASSEMBLY,FIRST STAGE
Possible match (shared part number)Norwalk Compreseer Company Inc Dba Norwalk Compressor Company
4320-01-254-9660815B-T63POSSIBLE MATCH
PUMP UNIT,CENTRIFUGAL
Possible match (shared part number)Oberdorfer Pumps Inc
8105-01-388-178133424POSSIBLE MATCH
BAG,TEXTILE
Possible match (shared part number)C & S Antennas, Inc Dba C & S Antennas Inc
1680-01-545-5310POSSIBLE MATCH
HOUSING ASSEMBLY,AI
Possible match (shared part number)
2910-01-588-281633424POSSIBLE MATCH
FILTER ELEMENT,FLUID
Possible match (shared part number)Wix Corp
5310-01-629-853333424POSSIBLE MATCH
WASHER,FLAT
Possible match (shared part number)Fastenal Company Dba Fastenal Co
6515-01-716-677933424POSSIBLE MATCH
CATHETER,URETHRAL
Possible match (shared part number)C. R. Bard, Inc.
NSN 6515-00-104-9006 is a Catheter,urethral, manufactured by Dow Silicones Corporation, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
What part numbers are listed for NSN 6515-00-104-9006?
NSN 6515-00-104-9006 has 4 manufacturer part numbers on file: 334-24 (Dow Corning Ltd), 334-24 (Dow Silicones Corporation), 266724 (C. R. Bard, Inc.), 166824CE (Bard Australia Pty Ltd).
What NSN replaces 6515-00-104-9006?
7 possible matches (shared part number, not a government interchangeability claim): 4310-00-883-0709, 4320-01-254-9660, 8105-01-388-1781. Verify interchangeability with system specifications before substitution.
What are the specifications of 334-24?
Key specifications for 334-24: Supplementary Features: D-DAY ITEM FOR DOD; Proximal End Funnel Quantity: 2; Style Designator: MODIFIED RETENTION; Design Designation: FOLEY. 10 specifications are documented in the U.S. Government catalog.
Is NSN 6515-00-104-9006 hazardous material?
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
Sources
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.
✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.