PartsTable TECHNICAL DATA SHEET
NSN 6510-01-735-6277Government record, cited

Dressing, Hemostatic6510-01-735-6277

NSN 6510-01-735-6277 · NIIN 017356277 · Part number 1131923
Mckesson Medical-Surgical Government Solutions Llc · FSC 6510 — Surgical Dressing Materials · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 1EU19
Government record, cited
NSN 6510-01-735-6277 — this item is cataloged by the U.S. Government under National Stock Number 6510-01-735-6277. Manufacturer of record part number: 1131923.
Also searched as  6510-01-735-6277 · 6510017356277 · NIIN 017356277 · 01-735-6277 · FSC 6510 Surgical Dressing Materials · CAGE 1EU19 · 1131923 · 6510NCM252151 · 4010 · 1712002 · 4010
Nearby stock numbers  ·
Features
  • Dressing,hemostatic — FSC 6510
  • 3 manufacturer part numbers on file
  • Manufacturer of record: Mckesson Medical-Surgical Government Solutions Llc
Identification
  • NSN: 6510-01-735-6277
  • NIIN: 017356277
  • FSC: 6510 — Surgical Dressing Materials
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 1131923
  • Manufacturer: Mckesson Medical-Surgical Government Solutions Llc
General Description

The Dressing,hemostatic, cataloged under National Stock Number 6510-01-735-6277, is classified within Federal Supply Class 6510 (Surgical Dressing Materials) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Mckesson Medical-Surgical Government Solutions Llc. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: BX.

Technical Specifications
ParameterValue
NSN6510-01-735-6277
Primary Part Number1131923
Item NameDressing,hemostatic
FSC / FSG6510 / 65 — Surgical Dressing Materials
ManufacturerMckesson Medical-Surgical Government Solutions Llc
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Unit of IssueBX
Cross-Reference Index
Part NumberManufacturer
1131923 PRIMARY Mckesson Medical-Surgical Government Solutions Llc (USA)
4010 PRIMARY Z-Medica, Llc Dba Z Medica (USA)
4010 PRIMARY Teleflex Medical Incorporated Dba Teleflex Medical Inc (USA)
Reference documents
ReferenceMeaning
6510NCM252151 5/1 Secondary reference
Defense Medical Standardization Board
1712002 5/1 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6510 — Surgical Dressing Materials
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6510-00-001-7644
6510-00-001-7644 · Item name not on file
6510-00-003-3058
ADHESIVE TIES,SURGICAL
6510-00-003-5103
6510-00-003-5103 · Item name not on file
6510-00-004-6680
6510-00-004-6680 · Item name not on file
6510-00-004-7870
6510-00-004-7870 · Item name not on file
6510-00-014-1002
6510-00-014-1002 · Item name not on file
6510-00-016-6415
6510-00-016-6415 · Item name not on file
6510-00-016-8155
6510-00-016-8155 · Item name not on file

Frequently Asked Questions

What is NSN 6510-01-735-6277?

NSN 6510-01-735-6277 is a Dressing,hemostatic, manufactured by Mckesson Medical-Surgical Government Solutions Llc, classified under FSC 6510, Surgical Dressing Materials. Status: active.

What part numbers are listed for NSN 6510-01-735-6277?

NSN 6510-01-735-6277 has 3 manufacturer part numbers on file: 1131923 (Mckesson Medical-Surgical Government Solutions Llc), 4010 (Z-Medica, Llc Dba Z Medica), 4010 (Teleflex Medical Incorporated Dba Teleflex Medical Inc).

What are the specifications of 1131923?

Key specifications for 1131923: Special Features: QUIKCLOT CONTROL+ 8X8, 2-PLY HEMOSTATIC DRESSING, BOX OF 10'S.RECOMMENDED USES:INTRA-ABDOMINAL PACKING: LIVER, SPLEEN,DAMAGE CONTROL. INTRA-THORACIC PACKING: CHEST, AROUND LUNGS, PELVIC PACKING, ILIAC RETRO-PERITONEAL PACKING: INFERIOR VENA CAVA, KIDNEY, DESCENDING AORTA, LARGE SOFT TISSUE WOUNDS, LARGE LACERATION, AMPUTATION, MACHINERY-RELATED WOUNDS, BURN DEBRIDEMENT, SOFT TISSUE FLAPS,NARROW PELVIS. SMALLER-SIZE INJURIES.; Part Name Assigned by Controlling Agency: DRESSING HEMOSTATIC 8X8. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6510-01-735-6277 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com