The Cable,power,electrical, cataloged under National Stock Number 6145-01-437-2674, is classified within Federal Supply Class 6145 (Wire and Cable, Electrical) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is Southwire Company Douglas Plant. Government technical data includes 16 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: FT.
| Parameter | Value |
|---|---|
| NSN | 6145-01-437-2674 |
| Primary Part Number | W4728 |
| Item Name | Cable,power,electrical |
| FSC / FSG | 6145 / 61 — Wire and Cable, Electrical |
| Manufacturer | Southwire Company Douglas Plant |
| Status | ACTIVE |
| Round Conductor Size | 18 AWG ALL CONDUCTORS |
| Temp Rating | -35.0 CELSIUS AND 90.0 CELSIUS DEGC |
| Voltage Rating | 300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
| Conductor Quantity | 2 |
| Strand Awg Size Per Conductor | 30 ALL CONDUCTORS |
| Cross-Sectional Shape Style | ROUND |
| Conductor Form | STRANDED ALL CONDUCTORS |
| Strand Quantity Per Conductor | 16 ALL CONDUCTORS |
| Conductor Arrangement and Quantity | 2 SINGLES |
| Color | BLACK SECOND POSITION JACKET CABLE |
| Color | WHITE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
| Color | BLACK FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
| Cross Section Outside Diameter | 0.290 INCHES NOMINAL IN |
| Material | RUBBER CHLOROSULFONATED POLYETHYLENE CLASS CSM SECOND POSITION JACKET CABLE |
| Material | RUBBER ETHYLENE-PROPYLENE CLASS EPM FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | FT |
| Acquisition advice code | JN |
| Part Number | Manufacturer |
|---|---|
| W4728 PRIMARY | Southwire Company Douglas Plant (USA) |
| Reference | Meaning |
|---|---|
| SC6145-0094-2 | 5/9 Secondary reference Drs Icas, Llc |
| W4728 | 3/9 Design control — primary reference U.S. Government activity |
NSN 6145-01-437-2674 is a Cable,power,electrical, manufactured by Southwire Company Douglas Plant, classified under FSC 6145, Wire and Cable, Electrical. Status: active.
NSN 6145-01-437-2674 has 1 manufacturer part number on file: W4728 (Southwire Company Douglas Plant).
Key specifications for W4728: Round Conductor Size: 18 AWG ALL CONDUCTORS; Temp Rating: -35.0 CELSIUS AND 90.0 CELSIUS DEGC; Voltage Rating: 300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS; Conductor Quantity: 2. 16 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.