The Cable,special Purpose,electrical, cataloged under National Stock Number 6145-01-374-1899, is classified within Federal Supply Class 6145 (Wire and Cable, Electrical) of the Electric Wire, Power, and Distribution Equipment group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 11 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: FT.
| Parameter | Value |
|---|---|
| NSN | 6145-01-374-1899 |
| Item Name | Cable,special Purpose,electrical |
| FSC / FSG | 6145 / 61 — Wire and Cable, Electrical |
| Status | ACTIVE |
| Round Conductor Size | 26 AWG ALL CONDUCTORS |
| Temp Rating | -65.0 CELSIUS AND 200.0 CELSIUS DEGC |
| Voltage Rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
| Surface Treatment Document and Classification | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE SECOND POSITION SHIELD BRAID METALLIC CABLE |
| Surface Treatment Document and Classification | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| Precious Material | SILVER |
| Conductor Quantity | 2 |
| Strand Awg Size Per Conductor | 38 ALL CONDUCTORS |
| Material Document and Classification | ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| Cross-Sectional Shape Style | ROUND |
| Conductor Form | STRANDED ALL CONDUCTORS |
| Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
| Conductor Arrangement and Quantity | 1 TWISTED PAIR |
| Color | WHITE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
| Color | BLACK FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
| Color | WHITE OR NATURAL THIRD POSITION JACKET CABLE |
| Surface Treatment | SILVER CORE CONDUCTOR ALL CONDUCTORS |
| Surface Treatment | SILVER SECOND POSITION SHIELD BRAID METALLIC CABLE |
| Precious Material and Location | SURFACE ALL CONDUCTORS SILVER AND SURFACE SHIELD BRAID SILVER |
| Cross Section Outside Diameter | 0.128 INCHES NOMINAL IN |
| Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| Material | COPPER SECOND POSITION SHIELD BRAID METALLIC CABLE |
| Material | PLASTIC FLUORINATED ETHYLENE PROPYLENE THIRD POSITION JACKET CABLE |
| Material | PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | FT |
| Acquisition advice code | JN |
| Weight | 0.0100 lbs |
| Cube | 0.0000 cu ft |
| Reference | Meaning |
|---|---|
| SM-A-800634-26 | 5/1 Secondary reference Amphenol Cable and Interconnect Technologies, Inc. |
| 960254-2262 | 5/9 Secondary reference Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp |
| 5265830-026 | 5/9 Secondary reference Naval Sea Systems Command |
| SM-A-800634-26 | 5/9 Secondary reference U.S. Government activity |
| MIL-DTL-55021/2 | 4/1 Identification reference U.S. Government activity |
| SM-A-800634-26 | 5/9 Secondary reference Calmont Engineering & Electronics Corp. Dba Calmont Wire & Cable, Inc. |
| E26C0-9SF | 2/2 Government specification standardization U.S. Government activity |
| SM-A-800634-26 | 5/9 Secondary reference National Wire and Cable Corporation Dba National Wire and Cable Div National Cable Molding Corporation |
| E26C9-0SF | 5/9 Secondary reference U.S. Government activity |
| SM-A-800634-26 | 5/9 Secondary reference Nexans Aerospace Usa Llc |
| EC26U9-0SF | 5/9 Secondary reference U.S. Government activity |
NSN 6145-01-374-1899 is a Cable,special Purpose,electrical, classified under FSC 6145, Wire and Cable, Electrical. Status: active.
Key specifications for 6145-01-374-1899: Round Conductor Size: 26 AWG ALL CONDUCTORS; Temp Rating: -65.0 CELSIUS AND 200.0 CELSIUS DEGC; Voltage Rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS; Surface Treatment Document and Classification: ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE SECOND POSITION SHIELD BRAID METALLIC CABLE. 24 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.