The Wire,electrical, cataloged under National Stock Number 6145-01-182-1383, is classified within Federal Supply Class 6145 (Wire and Cable, Electrical) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is Ge Aviation Systems Llc. Government technical data includes 12 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6145-01-182-1383 |
| Primary Part Number | SM1501E30-8 |
| Item Name | Wire,electrical |
| FSC / FSG | 6145 / 61 — Wire and Cable, Electrical |
| Manufacturer | Ge Aviation Systems Llc |
| Status | ACTIVE |
| Round Conductor Size | 30 AWG SINGLE CONDUCTOR |
| Temp Rating | 200.0 CELSIUS DEGC |
| Voltage Rating | 300.0 AC MAXIMUM RATED WORKING VOLTAGE SINGLE CONDUCTOR |
| Strand Awg Size Per Conductor | 38 SINGLE CONDUCTOR |
| Cross-Sectional Shape Style | ROUND |
| Conductor Form | STRANDED SINGLE CONDUCTOR |
| Strand Quantity Per Conductor | 7 SINGLE CONDUCTOR |
| Color | GRAY/GREY FIRST POSITION COVER SINGLE CONDUCTOR |
| Surface Treatment | SILVER CORE CONDUCTOR SINGLE CONDUCTOR |
| Cross Section Outside Diameter | 0.028 INCHES NOMINAL IN |
| Material | PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
| Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| SM1501E30-8 PRIMARY | Ge Aviation Systems Llc (USA) |
NSN 6145-01-182-1383 is a Wire,electrical, manufactured by Ge Aviation Systems Llc, classified under FSC 6145, Wire and Cable, Electrical. Status: active.
NSN 6145-01-182-1383 has 1 manufacturer part number on file: SM1501E30-8 (Ge Aviation Systems Llc).
Key specifications for SM1501E30-8: Round Conductor Size: 30 AWG SINGLE CONDUCTOR; Temp Rating: 200.0 CELSIUS DEGC; Voltage Rating: 300.0 AC MAXIMUM RATED WORKING VOLTAGE SINGLE CONDUCTOR; Strand Awg Size Per Conductor: 38 SINGLE CONDUCTOR. 12 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.