PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

UL62SOOW6BCF2/18EPCPECable,power,electrical

Underwriters Laboratories Inc · NSN 6145-01-061-3047 · FSC 6145 · No Item Name Available
Verified by PartsTable
NSN 6145-01-061-3047 — this item is cataloged by the U.S. Government under National Stock Number 6145-01-061-3047. Primary manufacturer part number: UL62SOOW6BCF2/18EPCPE.
Features
  • Cable,power,electrical — FSC 6145
  • Voltage Rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
  • Color: BLACK FIRST POSITION JACKET CABLE
  • Material: RUBBER FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
  • Material: COPPER CORE CONDUCTOR ALL CONDUCTORS
  • Strand Quantity Per Conductor: 19 ALL CONDUCTORS
  • Temp Rating: -20.0 CELSIUS AND 60.0 CELSIUS DEGC
  • Conductor Form: STRANDED ALL CONDUCTORS
Applications
  • Electrical power distribution
  • Signal transmission
  • Equipment interconnection
  • Applications requiring Rubber First Position Primary Insulation All Conductors construction
General Description

The Cable,power,electrical, cataloged under National Stock Number 6145-01-061-3047, is classified within Federal Supply Class 6145 (No Item Name Available) of the Electric Wire, Power, and Distribution Equipment group. The primary manufacturer of record is Underwriters Laboratories Inc. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: FT.

Technical Specifications
ParameterValue
NSN6145-01-061-3047
Primary Part NumberUL62SOOW6BCF2/18EPCPE
Item NameCable,power,electrical
FSC / FSG6145 / 61 — No Item Name Available
ManufacturerUnderwriters Laboratories Inc
StatusACTIVE
Voltage Rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
ColorBLACK FIRST POSITION JACKET CABLE
MaterialRUBBER FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
Strand Quantity Per Conductor19 ALL CONDUCTORS
Temp Rating-20.0 CELSIUS AND 60.0 CELSIUS DEGC
Conductor FormSTRANDED ALL CONDUCTORS
Conductor Arrangement and Quantity2 SINGLES
Strand Awg Size Per Conductor30 ALL CONDUCTORS
ColorWHITE CORE CONDUCTOR FIRST CONDUCTOR
MaterialRUBBER CHLOROPRENE CLASS CR FIRST POSITION JACKET CABLE
ColorBLACK CORE CONDUCTOR SECOND CONDUCTOR
Conductor Quantity2
Cross-Sectional Shape StyleROUND
Round Conductor Size18 AWG ALL CONDUCTORS
Cross Section Outside Diameter0.390 INCHES NOMINAL IN
Voltage Rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
ColorBLACK FIRST POSITION JACKET CABLE
MaterialRUBBER FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
Strand Quantity Per Conductor19 ALL CONDUCTORS
Temp Rating-20.0 CELSIUS AND 60.0 CELSIUS DEGC
Conductor FormSTRANDED ALL CONDUCTORS
Conductor Arrangement and Quantity2 SINGLES
Strand Awg Size Per Conductor30 ALL CONDUCTORS
ColorWHITE CORE CONDUCTOR FIRST CONDUCTOR
MaterialRUBBER CHLOROPRENE CLASS CR FIRST POSITION JACKET CABLE
ColorBLACK CORE CONDUCTOR SECOND CONDUCTOR
Conductor Quantity2
Cross-Sectional Shape StyleROUND
Lifecycle & Compliance
Acquisition StatusACTIVE
Successor6145-00-051-8477
HAZMATNo
Shelf Life Code0
Criticality CodeN
Unit of IssueFT
SMR CodeZN
Weight0.0700 lbs
Cube0.0017 cu ft
Verified Substitutes 12
Cable,power,electrical
6145-00-061-20751952 SUCCESSOR
Cable,power,electrical
Belden, Inc.
6145-00-089-5627UL62SJ3BCK3/16EPCPE SUCCESSOR
Cord,electrical
Underwriters Laboratories Inc
Cable,power,electrical
Cable,power,electrical
6145-00-117-8859UL62SE6BCF2/14TPETPE SUCCESSOR
Cable,power,electrical
Underwriters Laboratories Inc
Cable,power,electrical
Cable,power,electrical
Cable,power,electrical
Cable,power,electrical
Cross-Reference Index
Part NumberManufacturer
UL62SOOW6BCF2/18EPCPE PRIMARY Underwriters Laboratories Inc (USA)
1934 Belden, Inc. (USA)
UL62 Underwriters Laboratories Inc (USA)
J-C-580SOCF2/18RNJ Federal Specifications Promulgated by General Services Administration Washington DC (USA)
J-C-580 Federal Specifications Promulgated by General Services Administration Washington DC (USA)
Related Parts
SUCCESSOR 6145-00-051-8477 Cable,power,electrical
6145-00-061-2075SUCCESSOR
CABLE,POWER,ELECTRICAL
1952
6145-00-089-5627SUCCESSOR
CORD,ELECTRICAL
UL62SJ3BCK3/16EPCPE
6145-00-112-8671SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-117-8852SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-117-8859SUCCESSOR
CABLE,POWER,ELECTRICAL
UL62SE6BCF2/14TPETPE
6145-00-164-6948SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-188-3643SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-188-3657SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-191-3275SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-191-3297SUCCESSOR
CABLE,POWER,ELECTRICAL
6145-00-191-3588SUCCESSOR
CABLE,POWER,ELECTRICAL

Frequently Asked Questions

What is NSN 6145-01-061-3047?

NSN 6145-01-061-3047 is a Cable,power,electrical, manufactured by Underwriters Laboratories Inc, classified under FSC 6145 (No Item Name Available). Status: active.

What are the part numbers for NSN 6145-01-061-3047?

NSN 6145-01-061-3047 has 5 cross-referenced part numbers: UL62SOOW6BCF2/18EPCPE (Underwriters Laboratories Inc), 1934 (Belden, Inc.), UL62 (Underwriters Laboratories Inc), J-C-580SOCF2/18RNJ (Federal Specifications Promulgated by General Services Administration Washington DC), J-C-580 (Federal Specifications Promulgated by General Services Administration Washington DC).

What NSN replaces 6145-01-061-3047?

There are 12 known substitutes for 6145-01-061-3047: 6145-00-051-8477, 6145-00-061-2075, 6145-00-089-5627 and 9 more. Verify interchangeability with system specifications before substitution.

What are the specifications of UL62SOOW6BCF2/18EPCPE?

Key specifications for UL62SOOW6BCF2/18EPCPE: Voltage Rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS; Color: BLACK FIRST POSITION JACKET CABLE; Material: RUBBER FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS; Material: COPPER CORE CONDUCTOR ALL CONDUCTORS. 30 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.