PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

TYPE 3, 12 PAIR, 22AWGCable,telephone

Insulated Cable Engineers Assn Inc · NSN 6145-00-958-2026 · FSC 6145 · No Item Name Available
Verified by PartsTable
NSN 6145-00-958-2026 — this item is cataloged by the U.S. Government under National Stock Number 6145-00-958-2026. Primary manufacturer part number: TYPE 3, 12 PAIR, 22AWG.
Features
  • Cable,telephone — FSC 6145
  • Material: PLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
  • Cross Section Outside Diameter: 0.410 INCHES NOMINAL IN
  • Cross-Sectional Shape Style: ROUND
  • Material: PLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION JACKET CABLE
  • Round Conductor Size: 22 AWG ALL CONDUCTORS
  • Conductor Form: SOLID ALL CONDUCTORS
  • Material: COPPER CORE CONDUCTOR ALL CONDUCTORS
Applications
  • Electrical power distribution
  • Signal transmission
  • Equipment interconnection
  • Applications requiring Plastic First Position Primary Insulation All Conductors construction
General Description

The Cable,telephone, cataloged under National Stock Number 6145-00-958-2026, is classified within Federal Supply Class 6145 (No Item Name Available) of the Electric Wire, Power, and Distribution Equipment group. The primary manufacturer of record is Insulated Cable Engineers Assn Inc. Government technical data includes 20 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 11 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: FT.

Technical Specifications
ParameterValue
NSN6145-00-958-2026
Primary Part NumberTYPE 3, 12 PAIR, 22AWG
Item NameCable,telephone
FSC / FSG6145 / 61 — No Item Name Available
ManufacturerInsulated Cable Engineers Assn Inc
StatusACTIVE
MaterialPLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
Cross Section Outside Diameter0.410 INCHES NOMINAL IN
Cross-Sectional Shape StyleROUND
MaterialPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION JACKET CABLE
Round Conductor Size22 AWG ALL CONDUCTORS
Conductor FormSOLID ALL CONDUCTORS
MaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
Conductor Quantity24
Color Coding Document601-212-88486 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Conductor Arrangement and Quantity12 TWISTED PAIR
MaterialPLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
Cross Section Outside Diameter0.410 INCHES NOMINAL IN
Cross-Sectional Shape StyleROUND
MaterialPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION JACKET CABLE
Round Conductor Size22 AWG ALL CONDUCTORS
Conductor FormSOLID ALL CONDUCTORS
MaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
Conductor Quantity24
Color Coding Document601-212-88486 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Conductor Arrangement and Quantity12 TWISTED PAIR
Lifecycle & Compliance
Acquisition StatusACTIVE
Successor6145-00-256-3745 (S-80-576 TYPE3 16PR 24AWG)
HAZMATNo
Shelf Life Code0
Criticality CodeN
Unit of IssueFT
SMR CodeJN
Weight0.7000 lbs
Cube0.0012 cu ft
Verified Substitutes 11
6145-00-256-3745S-80-576 TYPE3 16PR 24AWG SUCCESSOR
Cable,telephone
Insulated Cable Engineers Assn Inc
6145-00-170-4044AT7441D INTERCHANGEABLE
Cable,telephone
Lucent Technologies Inc Corporate Headquarters
6145-00-229-3866AT7441-75 INTERCHANGEABLE
Cable,telephone
Lucent Technologies Inc Corporate Headquarters
6145-00-229-3867 INTERCHANGEABLE
Cable,telephone
6145-00-823-2282S-80-576-TYPE 1 3CONDUCTOR 22AWG INTERCHANGEABLE
Cable,telephone
Insulated Cable Engineers Assn Inc
6145-00-894-1001CIT3949 INTERCHANGEABLE
Cable,telephone
Cableco Inc
6145-00-926-6443AT7441D50PR24AWG INTERCHANGEABLE
Cable,telephone
Lucent Technologies Inc Corporate Headquarters
6145-00-926-6444S-80-576TYPE325PR24AWG INTERCHANGEABLE
Cable,telephone
Insulated Cable Engineers Assn Inc
6145-00-926-6445S-80-576 CAT 3,6PR,24AWG INTERCHANGEABLE
Cable,telephone
Insulated Cable Engineers Assn Inc
5985-01-242-3920601212 INTERCHANGEABLE
Isolator,radio Frequency Reflect
Ryt Industries Inc
Cross-Reference Index
Part NumberManufacturer
TYPE 3, 12 PAIR, 22AWG PRIMARY Insulated Cable Engineers Assn Inc (USA)
601-212 Triangle Wire and Cable Inc (USA)
S-80-576 Insulated Cable Engineers Assn Inc (USA)
REA-PE-71 Solberga Mekanska Verkstads Ab (SWE)
Related Parts
SUCCESSOR 6145-00-256-3745 Cable,telephone · S-80-576 TYPE3 16PR 24AWG
6145-00-170-4044INTERCHANGEABLE
CABLE,TELEPHONE
AT7441D
6145-00-229-3866INTERCHANGEABLE
CABLE,TELEPHONE
AT7441-75
6145-00-229-3867INTERCHANGEABLE
CABLE,TELEPHONE
6145-00-823-2282INTERCHANGEABLE
CABLE,TELEPHONE
S-80-576-TYPE 1 3CONDUCTOR 22AWG
6145-00-894-1001INTERCHANGEABLE
CABLE,TELEPHONE
CIT3949
6145-00-926-6443INTERCHANGEABLE
CABLE,TELEPHONE
AT7441D50PR24AWG
6145-00-926-6444INTERCHANGEABLE
CABLE,TELEPHONE
S-80-576TYPE325PR24AWG
6145-00-926-6445INTERCHANGEABLE
CABLE,TELEPHONE
S-80-576 CAT 3,6PR,24AWG
5985-01-242-3920INTERCHANGEABLE
ISOLATOR,RADIO FREQUENCY REFLECT
601212
4730-01-340-8695INTERCHANGEABLE
ELBOW,PIPE
601-2-1/2

Frequently Asked Questions

What is NSN 6145-00-958-2026?

NSN 6145-00-958-2026 is a Cable,telephone, manufactured by Insulated Cable Engineers Assn Inc, classified under FSC 6145 (No Item Name Available). Status: active.

What are the part numbers for NSN 6145-00-958-2026?

NSN 6145-00-958-2026 has 4 cross-referenced part numbers: TYPE 3, 12 PAIR, 22AWG (Insulated Cable Engineers Assn Inc), 601-212 (Triangle Wire and Cable Inc), S-80-576 (Insulated Cable Engineers Assn Inc), REA-PE-71 (Solberga Mekanska Verkstads Ab).

What NSN replaces 6145-00-958-2026?

There are 11 known substitutes for 6145-00-958-2026: 6145-00-256-3745, 6145-00-170-4044, 6145-00-229-3866 and 8 more. Verify interchangeability with system specifications before substitution.

What are the specifications of TYPE 3, 12 PAIR, 22AWG?

Key specifications for TYPE 3, 12 PAIR, 22AWG: Material: PLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS; Cross Section Outside Diameter: 0.410 INCHES NOMINAL IN; Cross-Sectional Shape Style: ROUND; Material: PLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION JACKET CABLE. 20 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com