The Cable,power,electrical, cataloged under National Stock Number 6145-00-935-2573, is classified within Federal Supply Class 6145 (Wire and Cable, Electrical) of the Electric Wire, Power, and Distribution Equipment group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: FT.
| Parameter | Value |
|---|---|
| NSN | 6145-00-935-2573 |
| Item Name | Cable,power,electrical |
| FSC / FSG | 6145 / 61 — Wire and Cable, Electrical |
| Status | ACTIVE |
| Round Conductor Size | 12 AWG ALL CONDUCTORS |
| Voltage Rating | 1000.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
| Conductor Quantity | 2 |
| Strand Awg Size Per Conductor | 25 ALL CONDUCTORS |
| Cross-Sectional Shape Style | ROUND |
| Conductor Form | STRANDED ALL CONDUCTORS |
| Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
| Conductor Arrangement and Quantity | 2 SINGLES |
| Color | WHITE FIRST POSITION COVER ALL CONDUCTORS |
| Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
| Cross Section Outside Diameter | 0.350 INCHES NOMINAL IN |
| Material | PLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION JACKET CABLE |
| Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| Material | PLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | FT |
| Acquisition advice code | JN |
| Weight | 0.0890 lbs |
| Cube | 0.0009 cu ft |
| Reference | Meaning |
|---|---|
| SMB602998 | 3/2 Design control — primary reference U.S. Government activity |
NSN 6145-00-935-2573 is a Cable,power,electrical, classified under FSC 6145, Wire and Cable, Electrical. Status: active.
Key specifications for 6145-00-935-2573: Round Conductor Size: 12 AWG ALL CONDUCTORS; Voltage Rating: 1000.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS; Conductor Quantity: 2; Strand Awg Size Per Conductor: 25 ALL CONDUCTORS. 14 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.