The Battery,storage, cataloged under National Stock Number 6140-01-413-0542, is classified within Federal Supply Class 6140 (Batteries, Rechargeable) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is Drs Network & Imaging Systems, Llc Dba Drs Technologies. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6140-01-413-0542 |
| Primary Part Number | 9900-03378-0000 |
| Item Name | Battery,storage |
| FSC / FSG | 6140 / 61 — Batteries, Rechargeable |
| Manufacturer | Drs Network & Imaging Systems, Llc Dba Drs Technologies |
| Status | ACTIVE |
| Terminal Quantity | 1 |
| Voltage in Volts | 6.0 |
| Battery Electrolyte | POTASSIUM HYDROXIDE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Hazardous per DLA record (HMIC Y) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 9900-03378-0000 PRIMARY | Drs Network & Imaging Systems, Llc Dba Drs Technologies (USA) |
| Reference | Meaning |
|---|---|
| 13385904 | 7/2 Vendor item drawing reference Us Army Aviation and Missile Command |
| 9900-02710-0000 | 5/9 Secondary reference Drs Tactical Systems Global Services, Inc. |
| 9800-03378-0000 | 5/9 Secondary reference Drs Network & Imaging Systems, Llc Dba Drs Technologies |
NSN 6140-01-413-0542 is a Battery,storage, manufactured by Drs Network & Imaging Systems, Llc Dba Drs Technologies, classified under FSC 6140, Batteries, Rechargeable. Status: active.
NSN 6140-01-413-0542 has 1 manufacturer part number on file: 9900-03378-0000 (Drs Network & Imaging Systems, Llc Dba Drs Technologies).
Key specifications for 9900-03378-0000: Overall Height: 1.400 INCHES NOMINAL IN; Terminal Quantity: 1; Voltage in Volts: 6.0; Overall Length: 11.940 INCHES NOMINAL IN. 3 specifications are documented in the U.S. Government catalog.
Hazardous per DLA record (HMIC Y). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.