The Generator,direct Current, cataloged under National Stock Number 6115-00-142-8639, is classified within Federal Supply Class 6115 (Generators and Generator Sets, Electrical) of the Electric Wire, Power, and Distribution Equipment group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6115-00-142-8639 |
| Item Name | Generator,direct Current |
| FSC / FSG | 6115 / 61 — Generators and Generator Sets, Electrical |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 12 UNTHREADED HOLE(S)12 UNTHREADED HOLE(S) |
| Duty Cycle | CONTINUOUSCONTINUOUS |
| Winding Type | SHUNT WOUNDSHUNT WOUND |
| Shaft Rotation Direction | COUNTERCLOCKWISE SINGLE ENDCOUNTERCLOCKWISE SINGLE END |
| Mounting Facility Circle Diameter | 5.000 INCHES5.000 INCHES IN |
| Maximum Operating Altitude Rating | 50000.0 FEET50000.0 FEET FT |
| Connection Type and Voltage Rating in Volts | 28.5 LINE TO NEUTRAL SINGLE OUTPUT28.5 LINE TO NEUTRAL SINGLE OUTPUT |
| Length of Shaft From Housing | 1.625 INCHES SINGLE END1.625 INCHES SINGLE END IN |
| Enclosure Feature | DUSTPROOFDUSTPROOF |
| Power Rating | 2.800 KILOWATTS INPUT2.800 KILOWATTS INPUT |
| Shaft End Characteristic | A14 SINGLE STYLE SINGLE ENDA14 SINGLE STYLE SINGLE END |
| Excitor Type | SELF-EXCITEDSELF-EXCITED |
| Rotor Speed Rating in RPM | 4500.0 SINGLE FULL LOAD4500.0 SINGLE FULL LOAD |
| Temp Rating | 40.0 AMBIENT CELSIUS AND 40.0 AMBIENT CELSIUS AND 30.0 OPERATING CELSIUS30.0 OPERATING CELSIUS |
| Inclosure Specification | COMMERCIALCOMMERCIAL |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 1106711 | C/1 Advisory reference — outside the item-of-supply concept Borgwarner Pds (anderson), L.l.c. |
| 1106711 | C/1 Advisory reference — outside the item-of-supply concept General Motors Llc Dba General Motors Llc |
| 95-32274TYPE0-1 | 5/9 Secondary reference U.S. Government activity |
| 1106711 | 5/9 Secondary reference General Motors Corp |
| 1106711 | 3/9 Design control — primary reference General Motors Corp Delco Remy Div |
NSN 6115-00-142-8639 is a Generator,direct Current, classified under FSC 6115, Generators and Generator Sets, Electrical. Status: active.
Key specifications for 6115-00-142-8639: Mounting Facility Type and Quantity: 12 UNTHREADED HOLE(S)12 UNTHREADED HOLE(S); Duty Cycle: CONTINUOUSCONTINUOUS; Overall Length: 13.844 INCHES13.844 INCHES IN; Winding Type: SHUNT WOUNDSHUNT WOUND. 15 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.