The Contactor,magnetic, cataloged under National Stock Number 6110-01-596-2865, is classified within Federal Supply Class 6110 (Electrical Control Equipment) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc. Government technical data includes 10 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6110-01-596-2865 |
| Primary Part Number | 6957ED29-4BQ |
| Item Name | Contactor,magnetic |
| FSC / FSG | 6110 / 61 — Electrical Control Equipment |
| Manufacturer | Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc |
| Status | ACTIVE |
| Actuation Method | MAGNETIC |
| Duty Cycle | CONTINUOUS |
| AC Voltage Rating | 440.0 KILOVOLTS NOMINAL |
| Control Type | LOCAL |
| Horsepower Rating | 25.0 |
| National Electrical Manufacturers Association Standards Design | DESIGNED PER NEMA STD |
| Operating Voltage Characteristic | FULL |
| Amp Size Rating | 15.0 |
| Ambient Temp | 50.0 CELSIUS DEGC |
| Performance Type | AUTOMATIC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 6957ED29-4BQ PRIMARY | Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc (USA) |
NSN 6110-01-596-2865 is a Contactor,magnetic, manufactured by Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc, classified under FSC 6110, Electrical Control Equipment. Status: active.
NSN 6110-01-596-2865 has 1 manufacturer part number on file: 6957ED29-4BQ (Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc).
Key specifications for 6957ED29-4BQ: Actuation Method: MAGNETIC; Overall Height: 4.000 INCHES NOMINAL IN; Duty Cycle: CONTINUOUS; AC Voltage Rating: 440.0 KILOVOLTS NOMINAL. 10 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.