The Conditioner,power Line, cataloged under National Stock Number 6110-01-595-6479, is classified within Federal Supply Class 6110 (Electrical Control Equipment) of the Electric Wire, Power, and Distribution Equipment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6110-01-595-6479 |
| Item Name | Conditioner,power Line |
| FSC / FSG | 6110 / 61 — Electrical Control Equipment |
| Status | ACTIVE |
| Supplementary Features | ATALINE SURGE PROTECTION NETWORK/PHONE LINE - RJ-45 OUTPUT WAVEFORM: SINEWAVE, SURGE SUPPRESSION STANDARD SURGE ENERGY RATING: 570 JOULES CIRCUIT PROTECTION CIRCUIT BREAKER BATTERY TYPE: EXPANDABLE TECHNOLOGY LEAD ACID VOLTAGE PROVIDED: 48 V, RUN TIME: (UP TO) 4.5 MIN AT FULL LOAD RECHARGE TIME 6 HOUR(S) V |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Reference | Meaning |
|---|---|
| FABSV2-PC120 | 3/2 Design control — primary reference U.S. Government activity |
NSN 6110-01-595-6479 is a Conditioner,power Line, classified under FSC 6110, Electrical Control Equipment. Status: active.
Key specifications for 6110-01-595-6479: Supplementary Features: ATALINE SURGE PROTECTION NETWORK/PHONE LINE - RJ-45 OUTPUT WAVEFORM: SINEWAVE, SURGE SUPPRESSION STANDARD SURGE ENERGY RATING: 570 JOULES CIRCUIT PROTECTION CIRCUIT BREAKER BATTERY TYPE: EXPANDABLE TECHNOLOGY LEAD ACID VOLTAGE PROVIDED: 48 V, RUN TIME: (UP TO) 4.5 MIN AT FULL LOAD RECHARGE TIME 6 HOUR(S) V; Special Features: FABS V2 120V POWER CONDITIONER WITH UPS. INCLUDES (1) FURMAN PL-PRO DMC POWER CONDITIONER, (1) TRIPP LITE SMART ONLINE 1500VA UPS, AND (1) SUPPORT PACKAGING CASE AND CONNECTORS. MAXIMUM OUTPUT CURRENT: 15 AMPS. LINE CORD: CAPTIVE 3/14 AWG, 10 FT. BLACK CORD WITH NEMA 15 PLUG, PULL-OUT LIGHTS: TWO MULTI-LED, DIMMABLE LAMPS, BNC SOCKET W/SWITCH: REAR RACK LAMP, 12VAC 500MA MAXX (LAMP NOT INCLUDED), OPERATING VOLTAGE: 90 TO 139 VAC SPIKE PROTECTION MODE: LINE TO NEUTRAL, ZERO GROUND LEAKAGE, SPIKE CLAMPING VOLTAGE: 188 VAC PEAK @ 3,000 AMPS, RESPONSE TIME: 1 NANOSECOND, MAXIMUM SURGE CURRENT: 6,500 AMPS, NOISE ATTENUATION: 10 DB @ 10 KHZ, 40 DB @ 100 KHZ, 50 DB @ 500 KHZ , UPS SPECIFICATIONS: ON-LINE INPUT VOLTAGE: AC 100/110/120 V INPUT VOLTAGE RANGE: AC 65 - 138 V, FREQUENCY REQUIRED: 50/60 HZ, INPUT CONNECTOR(S): 1 X POWER NEMA 5-15, OUTPUT VOLTAGE: AC 100/110/120 V 2% ( 50/60 HZ ), POWER OUTPUT CONNECTORS DETAILS: 6 X POWER NEMA 5-15, POWER PROVIDED: 1.2 KW/ 1500 VA D KHz. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.