The Panel,power Distribution, cataloged under National Stock Number 6110-01-192-6322, is classified within Federal Supply Class 6110 (Electrical Control Equipment) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6110-01-192-6322 |
| Primary Part Number | 976-1-1X76 UNIT B |
| Item Name | Panel,power Distribution |
| FSC / FSG | 6110 / 61 — Electrical Control Equipment |
| Manufacturer | Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc |
| Status | ACTIVE |
| Supplementary Features | REACTOR FRESH WATER COOLING PUMP NO. 1 CONTROL APPLICATION |
| Input Voltage Rating | 440.0 AC VOLTS NOMINAL LOCATION NOT OTHERWISE SPECIFIED |
| Panel Quantity | 1 |
| Electrical Input Quantity | 1 |
| Input Phase | THREE LOCATION NOT OTHERWISE SPECIFIED |
| Enclosure Feature | PARTIALLY ENCLOSED |
| Input Frequency in Hertz | 60.0 LOCATION NOT OTHERWISE SPECIFIED |
| Current Rating in Amps | 32.0 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 976-1-1X76 UNIT B PRIMARY | Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc (USA) |
| Reference | Meaning |
|---|---|
| 976-1-1X76UNITB | C/1 Advisory reference — outside the item-of-supply concept Eaton Corp Opns & Technical Center |
NSN 6110-01-192-6322 is a Panel,power Distribution, manufactured by Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc, classified under FSC 6110, Electrical Control Equipment. Status: active.
NSN 6110-01-192-6322 has 1 manufacturer part number on file: 976-1-1X76 UNIT B (Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc).
Key specifications for 976-1-1X76 UNIT B: Overall Height: 12.500 INCHES NOMINAL IN; Supplementary Features: REACTOR FRESH WATER COOLING PUMP NO. 1 CONTROL APPLICATION; Overall Width: 20.000 INCHES NOMINAL IN; Input Voltage Rating: 440.0 AC VOLTS NOMINAL LOCATION NOT OTHERWISE SPECIFIED. 8 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.