The Contractor,magnetic, cataloged under National Stock Number 6110-01-134-9403, is classified within Federal Supply Class 6110 (Electrical Control Equipment) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is Ametek Inc Div Ametek Switch. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6110-01-134-9403 |
| Primary Part Number | JCG-6007A |
| Item Name | Contractor,magnetic |
| FSC / FSG | 6110 / 61 — Electrical Control Equipment |
| Manufacturer | Ametek Inc Div Ametek Switch |
| Status | ACTIVE |
| General Characteristics Item Description | CONTACTS: 3 PST NO DOUBLE BREAK,VOLTAGE: 25 VDC,FREQUENCY: DC,CURRENT: 250 AMP PER POLE,4.840 IN. W,5.555 IN. H VDC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| JCG-6007A PRIMARY | Ametek Inc Div Ametek Switch (USA) |
| Reference | Meaning |
|---|---|
| 13026602 | 7/2 Vendor item drawing reference Us Army Aviation and Missile Command |
| HB200BE | 5/9 Secondary reference Prestolite Electric Inc |
| 6170115-1 | 5/2 Secondary reference U.S. Government activity |
NSN 6110-01-134-9403 is a Contractor,magnetic, manufactured by Ametek Inc Div Ametek Switch, classified under FSC 6110, Electrical Control Equipment. Status: active.
NSN 6110-01-134-9403 has 1 manufacturer part number on file: JCG-6007A (Ametek Inc Div Ametek Switch).
Key specifications for JCG-6007A: General Characteristics Item Description: CONTACTS: 3 PST NO DOUBLE BREAK,VOLTAGE: 25 VDC,FREQUENCY: DC,CURRENT: 250 AMP PER POLE,4.840 IN. W,5.555 IN. H VDC. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.