The Monitor,wattmeter and Reverse Cu, cataloged under National Stock Number 6110-00-945-1008, is classified within Federal Supply Class 6110 (Electrical Control Equipment) of the Electric Wire, Power, and Distribution Equipment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6110-00-945-1008 |
| Item Name | Monitor,wattmeter and Reverse Cu |
| FSC / FSG | 6110 / 61 — Electrical Control Equipment |
| Status | ACTIVE |
| General Characteristics Item Description | CONSIST OF OVERALL LENGTH 6.5IN;WIDTH 3.0IN;DEPTH 5.0IN;INPUT VOLTAGE AND CURRENT PHASE 1-120V TO TERMINAL 1 AND 2,+24VDC TO TERMINAL 9/0-1.5AMP RMS TO TERMINAL 12 AND 13;PHASE 2-120V TO TERMINAL 3 AND 4,-24VDC TO TERMINAL 7/0-1.5AMP RMS TO TERMINAL 14 AND 15;PHASE 3-120V TO TERMINAL 5 AND 6/0-1.5AMP RMS TO TERMINAL 16 AND 17;OPERATIONAL DATA-REVERSE CURRENT RELAY SET TO OPERATE AT -10PERCENT POWER W/ADJUSTABLE TIME DELAY FROM 2-10 SECONDS VDC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 64D41604 | 5/9 Secondary reference U.S. Government activity |
| 0000-3605 | 3/9 Design control — primary reference U.S. Government activity |
NSN 6110-00-945-1008 is a Monitor,wattmeter and Reverse Cu, classified under FSC 6110, Electrical Control Equipment. Status: active.
Key specifications for 6110-00-945-1008: General Characteristics Item Description: CONSIST OF OVERALL LENGTH 6.5IN;WIDTH 3.0IN;DEPTH 5.0IN;INPUT VOLTAGE AND CURRENT PHASE 1-120V TO TERMINAL 1 AND 2,+24VDC TO TERMINAL 9/0-1.5AMP RMS TO TERMINAL 12 AND 13;PHASE 2-120V TO TERMINAL 3 AND 4,-24VDC TO TERMINAL 7/0-1.5AMP RMS TO TERMINAL 14 AND 15;PHASE 3-120V TO TERMINAL 5 AND 6/0-1.5AMP RMS TO TERMINAL 16 AND 17;OPERATIONAL DATA-REVERSE CURRENT RELAY SET TO OPERATE AT -10PERCENT POWER W/ADJUSTABLE TIME DELAY FROM 2-10 SECONDS VDC; End Item Identification: EMU-10 AND /MS GENERATOR SET. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.