PartsTable TECHNICAL DATA SHEET
NSN 6105-01-034-4009Government record, cited

Motor, Direct Current6105-01-034-4009

NSN 6105-01-034-4009 · NIIN 010344009 · Part number 5CD164TD801A802
General Electric Co Direct Current Motor and Generator Dept · FSC 6105 — Motors, Electrical · FSG 61 — Electric Wire, Power, and Distribution Equipment · CAGE 01288
Government record, cited
NSN 6105-01-034-4009 — this item is cataloged by the U.S. Government under National Stock Number 6105-01-034-4009. Manufacturer of record part number: 5CD164TD801A802.
Also searched as  6105-01-034-4009 · 6105010344009 · NIIN 010344009 · 01-034-4009 · FSC 6105 Motors, Electrical · CAGE 01288 · 5CD164TD801A802 · SM-A-719463
Nearby stock numbers  ·
Features
  • Motor,direct Current — FSC 6105
  • Keyway Depth: 0.3750 INCHES NOMINAL SINGLE END IN
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • FSC Application Data: COMMUNICATION-TELEMETRY-TRACKING SYSTEMS,NONAIRBORNE
  • Duty Cycle: CONTINUOUS
  • Shaft Diameter: 1.6245 INCHES NOMINAL SINGLE END IN
  • Winding Type: SHUNT WOUND
  • Mounting Method: FACE
Identification
  • NSN: 6105-01-034-4009
  • NIIN: 010344009
  • FSC: 6105 — Motors, Electrical
  • FSG: 61 — Electric Wire, Power, and Distribution Equipment
  • Primary part number: 5CD164TD801A802
  • Manufacturer: General Electric Co Direct Current Motor and Generator Dept
General Description

The Motor,direct Current, cataloged under National Stock Number 6105-01-034-4009, is classified within Federal Supply Class 6105 (Motors, Electrical) of the Electric Wire, Power, and Distribution Equipment group. The manufacturer of record is General Electric Co Direct Current Motor and Generator Dept. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6105-01-034-4009
Primary Part Number5CD164TD801A802
Item NameMotor,direct Current
FSC / FSG6105 / 61 — Motors, Electrical
ManufacturerGeneral Electric Co Direct Current Motor and Generator Dept
StatusACTIVE
Keyway Depth0.3750 INCHES NOMINAL SINGLE END IN
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
FSC Application DataCOMMUNICATION-TELEMETRY-TRACKING SYSTEMS,NONAIRBORNE
Duty CycleCONTINUOUS
Shaft Diameter1.6245 INCHES NOMINAL SINGLE END IN
Winding TypeSHUNT WOUND
Mounting MethodFACE
Frame Size Designation259ADY
Cooling MethodAMBIENT AIR
Shaft Rotation DirectionCLOCKWISE OR COUNTERCLOCKWISE SINGLE END
Mounting Facility Circle Diameter12.500 INCHES IN
Maximum Operating Altitude Rating40000.0 FEET FT
Connection Type and Voltage Rating in Volts240.0 LINE TO NEUTRAL SINGLE INPUT
Specific UseANTENNA DRIVE TG-232/FSC
Keyway Length2.2500 INCHES NOMINAL SINGLE END IN
Bearing TypeANNULAR BALL
Keyway Width0.3750 INCHES NOMINAL SINGLE END IN
Length of Shaft From Housing4.660 INCHES SINGLE END IN
Enclosure FeatureTOTALLY ENCLOSED
Test Data Document80063-SM-A-719463 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Power Rating10.0000 HORSEPOWER OUTPUT
Shaft End CharacteristicA9 SINGLE STYLE SINGLE END
Terminal Type and Quantity4 THREADED STUD
Inclosure SpecificationNEMA
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
5CD164TD801A802 General Electric Co Direct Current Motor and Generator Dept (USA)
Reference documents
ReferenceMeaning
SM-A-719463 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6105 — Motors, Electrical
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6105-00-001-1471
6105-00-001-1471 · Item name not on file
6105-00-001-1473
6105-00-001-1473 · Item name not on file
6105-00-001-1497
6105-00-001-1497 · Item name not on file
6105-00-001-1710
6105-00-001-1710 · Item name not on file
6105-00-001-1712
MOTOR,ALTERNATING CURRENT
6105-00-001-2097
6105-00-001-2097 · Item name not on file
6105-00-001-2098
6105-00-001-2098 · Item name not on file
6105-00-001-3680
MOTOR,DIRECT CURRENT

Frequently Asked Questions

What is NSN 6105-01-034-4009?

NSN 6105-01-034-4009 is a Motor,direct Current, manufactured by General Electric Co Direct Current Motor and Generator Dept, classified under FSC 6105, Motors, Electrical. Status: active.

What part numbers are listed for NSN 6105-01-034-4009?

NSN 6105-01-034-4009 has 1 manufacturer part number on file: 5CD164TD801A802 (General Electric Co Direct Current Motor and Generator Dept).

What are the specifications of 5CD164TD801A802?

Key specifications for 5CD164TD801A802: Keyway Depth: 0.3750 INCHES NOMINAL SINGLE END IN; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); FSC Application Data: COMMUNICATION-TELEMETRY-TRACKING SYSTEMS,NONAIRBORNE; Duty Cycle: CONTINUOUS. 24 specifications are documented in the U.S. Government catalog.

Is NSN 6105-01-034-4009 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com