The Dummy Load,electrical, cataloged under National Stock Number 5985-01-729-0654, is classified within Federal Supply Class 5985 (Antennas, Waveguides, and Related Equipment) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5985-01-729-0654 |
| Item Name | Dummy Load,electrical |
| FSC / FSG | 5985 / 59 — Antennas, Waveguides, and Related Equipment |
| Status | ACTIVE |
| Operating Position | HORIZONTAL |
| Termination Type | CONNECTION COAXIAL |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 57.15 MILLIMETERS NOMINAL MM |
| Precious Material | GOLD |
| Body Width | 80.0 MILLIMETERS NOMINAL MM |
| Body Height | 80.0 MILLIMETERS NOMINAL MM |
| Style Designator | RF CONNECTOR, 4 HOLE OR CUSHION MOUNTED |
| Cooling Method | SELF-COOLED |
| Connector End Design | MALE |
| Impedance Rating in Ohms | 50.0 NOMINAL |
| Body Length | 137.1 MILLIMETERS NOMINAL MM |
| Frequency Range Rating | +0.0 TO 6.0 GIGAHERTZ |
| Precious Material and Location | BERYLLIUM GOLD |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 57.15 MILLIMETERS NOMINAL MM |
| Power Rating | 150.0 WATTS AVERAGE |
| Coaxial Connector Series Designation | N |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 1435-4 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5985-01-729-0654 is a Dummy Load,electrical, classified under FSC 5985, Antennas, Waveguides, and Related Equipment. Status: active.
Key specifications for 5985-01-729-0654: Operating Position: HORIZONTAL; Termination Type: CONNECTION COAXIAL; Overall Height: 80.0 MILLIMETERS NOMINAL MM; Center to Center Distance Between Mounting Facilities Parallel to Length: 57.15 MILLIMETERS NOMINAL MM. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.