The Waveguide Assembly, cataloged under National Stock Number 5985-01-093-6019, is classified within Federal Supply Class 5985 (Antennas, Waveguides, and Related Equipment) of the Electrical and Electronic Equipment Components group. The manufacturer of record is L3 Technologies, Inc. Div L3 Keo. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5985-01-093-6019 |
| Primary Part Number | 060037 |
| Item Name | Waveguide Assembly |
| FSC / FSG | 5985 / 59 — Antennas, Waveguides, and Related Equipment |
| Manufacturer | L3 Technologies, Inc. Div L3 Keo |
| Status | ACTIVE |
| FSC Application Data | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENTSEAMLESS SINGLE TUBING SEGMENT |
| Flange Inside Height | 0.168 INCHES MINIMUM AND 0.168 INCHES MINIMUM AND 0.172 INCHES MAXIMUM FIRST FLANGE0.172 INCHES MAXIMUM FIRST FLANGE IN |
| Flange Inside Height | 0.253 INCHES MINIMUM AND 0.253 INCHES MINIMUM AND 0.255 INCHES MAXIMUM SECOND FLANGE0.255 INCHES MAXIMUM SECOND FLANGE IN |
| Flange Quantity | 22 |
| Style Designator | BEND TYPE |
| Waveguide Offset Distance | 0.910 INCHES MINIMUM AND 0.970 INCHES MAXIMUM IN |
| Flexibility | RIGID SINGLE TUBING SEGMENT |
| Flange Inside Diameter | 0.610 INCHES MINIMUM AND 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM FIRST FLANGE0.640 INCHES MAXIMUM FIRST FLANGE IN |
| Waveguide Inside Width | 0.418 INCHES MINIMUM AND 0.418 INCHES MINIMUM AND 0.422 INCHES MAXIMUM0.422 INCHES MAXIMUM IN |
| Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULARINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| Flange Outside Height | 0.860 INCHES MINIMUM AND 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM FIRST FLANGE0.890 INCHES MAXIMUM FIRST FLANGE IN |
| Flange Outside Height | 0.860 INCHES MINIMUM AND 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM SECOND FLANGE0.890 INCHES MAXIMUM SECOND FLANGE IN |
| Flange Connecting Hole Diameter | 0.116 INCHES MINIMUM AND 0.116 INCHES MINIMUM AND 0.118 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES0.118 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES IN |
| Flange Inside Width | 0.418 INCHES MINIMUM AND 0.418 INCHES MINIMUM AND 0.422 INCHES MAXIMUM FIRST FLANGE0.422 INCHES MAXIMUM FIRST FLANGE IN |
| Flange Inside Width | 0.503 INCHES MINIMUM AND 0.503 INCHES MINIMUM AND 0.505 INCHES MAXIMUM SECOND FLANGE0.505 INCHES MAXIMUM SECOND FLANGE IN |
| Thread Direction | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIESRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
| Nominal Thread Size | 0.112 INCHES FIRST FLANGE ALL CONNECTION FACILITIES0.112 INCHES FIRST FLANGE ALL CONNECTION FACILITIES IN |
| Waveguide Outside Height | 0.247 INCHES MINIMUM AND 0.247 INCHES MINIMUM AND 0.253 INCHES MAXIMUM0.253 INCHES MAXIMUM IN |
| Waveguide Outside Width | 0.497 INCHES MINIMUM AND 0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM0.503 INCHES MAXIMUM IN |
| Flange Depth | 0.173 INCHES MINIMUM AND 0.173 INCHES MINIMUM AND 0.203 INCHES MAXIMUM SECOND FLANGE0.203 INCHES MAXIMUM SECOND FLANGE IN |
| Flange Depth | 0.270 INCHES MINIMUM AND 0.270 INCHES MINIMUM AND 0.300 INCHES MAXIMUM FIRST FLANGE0.300 INCHES MAXIMUM FIRST FLANGE IN |
| Flange Outside Width | 0.860 INCHES MINIMUM AND 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM FIRST FLANGE0.890 INCHES MAXIMUM FIRST FLANGE IN |
| Flange Outside Width | 0.860 INCHES MINIMUM AND 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM SECOND FLANGE0.890 INCHES MAXIMUM SECOND FLANGE IN |
| Insertion Loss in Decibels | 0.500.50 |
| Surface Treatment | PAINT ALL FLANGE OUTSIDE SURFACES |
| Surface Treatment | LACQUER ALL FLANGE INSIDE SURFACES |
| Waveguide Inside Height | 0.168 INCHES MINIMUM AND 0.168 INCHES MINIMUM AND 0.172 INCHES MAXIMUM0.172 INCHES MAXIMUM IN |
| Thread Class | 2B FIRST FLANGE ALL CONNECTION FACILITIES2B FIRST FLANGE ALL CONNECTION FACILITIES |
| Material | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL D — Destroy Item |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 055950 | L3 Technologies, Inc. Div L3 Keo (USA) |
| 060037 PRIMARY | L3 Technologies, Inc. Div L3 Keo (USA) |
| Reference | Meaning |
|---|---|
| 999C060037 | 5/9 Secondary reference L3 Technologies, Inc. Div L3 Keo |
| TR495010 | C/1 Advisory reference — outside the item-of-supply concept Microwave Engineering Corporation |
| 933C055950 | 5/9 Secondary reference L3 Technologies, Inc. Div L3 Keo |
NSN 5985-01-093-6019 is a Waveguide Assembly, manufactured by L3 Technologies, Inc. Div L3 Keo, classified under FSC 5985, Antennas, Waveguides, and Related Equipment. Status: active.
NSN 5985-01-093-6019 has 2 manufacturer part numbers on file: 055950 (L3 Technologies, Inc. Div L3 Keo), 060037 (L3 Technologies, Inc. Div L3 Keo).
3 possible matches (shared part number, not a government interchangeability claim): 3040-01-361-8197, 4130-01-486-9527, 6510-01-537-4175. Verify interchangeability with system specifications before substitution.
Key specifications for 060037: FSC Application Data: ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT; Tubing Wall Construction Style: SEAMLESS SINGLE TUBING SEGMENTSEAMLESS SINGLE TUBING SEGMENT; Flange Inside Height: 0.168 INCHES MINIMUM AND 0.168 INCHES MINIMUM AND 0.172 INCHES MAXIMUM FIRST FLANGE0.172 INCHES MAXIMUM FIRST FLANGE IN; Flange Inside Height: 0.253 INCHES MINIMUM AND 0.253 INCHES MINIMUM AND 0.255 INCHES MAXIMUM SECOND FLANGE0.255 INCHES MAXIMUM SECOND FLANGE IN. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
NSN 5985-01-093-6019 has DEMIL Code D. Demilitarization may be required before disposal or transfer to non-military entities.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.