PartsTable TECHNICAL DATA SHEET
NSN 5985-01-090-1624Government record, cited

Waveguide Assembly5985-01-090-1624

NSN 5985-01-090-1624 · NIIN 010901624
FSC 5985 — Antennas, Waveguides, and Related Equipment · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5985-01-090-1624 · 5985010901624 · NIIN 010901624 · 01-090-1624 · FSC 5985 Antennas, Waveguides, and Related Equipment
Nearby stock numbers  ·
Features
  • Waveguide Assembly — FSC 5985
  • FSC Application Data: ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
  • Tubing Wall Construction Style: SEAMLESS ALL TUBING SEGMENT
  • Flange Inside Height: 0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM FIRST FLANGE IN
  • Waveguide Height: 3.490 INCHES MINIMUM AND 3.510 INCHES MAXIMUM IN
  • Flange Quantity: 2
  • Bend Angle in Deg: 90.0 ALL BENDS E-PLANE
  • Style Designator: DOUBLE BEND TYPE
Identification
  • NSN: 5985-01-090-1624
  • NIIN: 010901624
  • FSC: 5985 — Antennas, Waveguides, and Related Equipment
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Waveguide Assembly, cataloged under National Stock Number 5985-01-090-1624, is classified within Federal Supply Class 5985 (Antennas, Waveguides, and Related Equipment) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5985-01-090-1624
Item NameWaveguide Assembly
FSC / FSG5985 / 59 — Antennas, Waveguides, and Related Equipment
StatusACTIVE
FSC Application DataANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
Tubing Wall Construction StyleSEAMLESS ALL TUBING SEGMENT
Flange Inside Height0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM FIRST FLANGE IN
Waveguide Height3.490 INCHES MINIMUM AND 3.510 INCHES MAXIMUM IN
Flange Quantity2
Bend Angle in Deg90.0 ALL BENDS E-PLANE
Style DesignatorDOUBLE BEND TYPE
FlexibilityRIGID ALL TUBING SEGMENT
Flange Inside Diameter0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM FIRST FLANGE IN
Waveguide Inside Width0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM IN
Cross-Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
Flange Outside Height1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM FIRST FLANGE IN
Waveguide Center to Center Distance3.480 INCHES MINIMUM AND 3.520 INCHES MAXIMUM IN
Flange Inside Width0.620 INCHES MINIMUM AND 0.624 INCHES MAXIMUM FIRST FLANGE IN
Thread DirectionRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
Nominal Thread Size0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES IN
Waveguide Outside Height0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM IN
Waveguide Outside Width0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM IN
Flange Depth0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM FIRST FLANGE IN
Flange Outside Width1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM FIRST FLANGE IN
Surface TreatmentCHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES
Surface TreatmentCHROMATE ZINC AND ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
Waveguide Inside Height0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM IN
Thread Class2B FIRST FLANGE ALL CONNECTION FACILITIES
MaterialALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
Flange Connecting Facility and Quantity4 THREADED HOLE(S) FIRST FLANGE ALL CONNECTION FACILITIES
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) FIRST FLANGE ALL CONNECTION FACILITIES
Flange StyleCHOKE TYPE FIRST FLANGE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL D — Destroy Item
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
861344-1 3/2 Design control — primary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5985-01-090-1624?

NSN 5985-01-090-1624 is a Waveguide Assembly, classified under FSC 5985, Antennas, Waveguides, and Related Equipment. Status: active.

What are the specifications of 5985-01-090-1624?

Key specifications for 5985-01-090-1624: FSC Application Data: ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT; Tubing Wall Construction Style: SEAMLESS ALL TUBING SEGMENT; Flange Inside Height: 0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM FIRST FLANGE IN; Waveguide Height: 3.490 INCHES MINIMUM AND 3.510 INCHES MAXIMUM IN. 28 specifications are documented in the U.S. Government catalog.

Is NSN 5985-01-090-1624 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5985-01-090-1624?

NSN 5985-01-090-1624 has DEMIL Code D. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com