PartsTable TECHNICAL DATA SHEET
NSN 5985-01-062-9420Government record, cited

Waveguide Assembly5985-01-062-9420

NSN 5985-01-062-9420 · NIIN 010629420
FSC 5985 — Antennas, Waveguides, and Related Equipment · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5985-01-062-9420 · 5985010629420 · NIIN 010629420 · 01-062-9420 · FSC 5985 Antennas, Waveguides, and Related Equipment · 17-15849-1 · 17-15849-1
Nearby stock numbers  ·
Features
  • Waveguide Assembly — FSC 5985
  • Tubing Wall Construction Style: SEAMLESS SINGLE TUBING SEGMENTSEAMLESS SINGLE TUBING SEGMENT
  • Flange Inside Height: 0.1386 INCHES MINIMUM AND 0.1386 INCHES MINIMUM AND 0.1414 INCHES MAXIMUM FIRST FLANGE0.1414 INCHES MAXIMUM FIRST FLANGE IN
  • Flange Inside Height: 0.220 INCHES MINIMUM AND 0.220 INCHES MINIMUM AND 0.224 INCHES MAXIMUM SECOND FLANGE0.224 INCHES MAXIMUM SECOND FLANGE IN
  • Flange Quantity: 22
  • Voltage Standing Wave Ratio: 1.081.08
  • Bend Angle in Deg: 45.0 ALL BENDS H-PLANE45.0 ALL BENDS H-PLANE
  • Style Designator: OFFSET BEND TYPE
Identification
  • NSN: 5985-01-062-9420
  • NIIN: 010629420
  • FSC: 5985 — Antennas, Waveguides, and Related Equipment
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Waveguide Assembly, cataloged under National Stock Number 5985-01-062-9420, is classified within Federal Supply Class 5985 (Antennas, Waveguides, and Related Equipment) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5985-01-062-9420
Item NameWaveguide Assembly
FSC / FSG5985 / 59 — Antennas, Waveguides, and Related Equipment
StatusACTIVE
Tubing Wall Construction StyleSEAMLESS SINGLE TUBING SEGMENTSEAMLESS SINGLE TUBING SEGMENT
Flange Inside Height0.1386 INCHES MINIMUM AND 0.1386 INCHES MINIMUM AND 0.1414 INCHES MAXIMUM FIRST FLANGE0.1414 INCHES MAXIMUM FIRST FLANGE IN
Flange Inside Height0.220 INCHES MINIMUM AND 0.220 INCHES MINIMUM AND 0.224 INCHES MAXIMUM SECOND FLANGE0.224 INCHES MAXIMUM SECOND FLANGE IN
Flange Quantity22
Voltage Standing Wave Ratio1.081.08
Bend Angle in Deg45.0 ALL BENDS H-PLANE45.0 ALL BENDS H-PLANE
Style DesignatorOFFSET BEND TYPE
FlexibilityRIGID SINGLE TUBING SEGMENT
Flange Inside Diameter0.485 INCHES MINIMUM AND 0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM FIRST FLANGE0.515 INCHES MAXIMUM FIRST FLANGE IN
Waveguide Inside Width0.2785 INCHES MINIMUM AND 0.2785 INCHES MINIMUM AND 0.2815 INCHES MAXIMUM0.2815 INCHES MAXIMUM IN
Cross-Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULARINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
Flange Outside Height0.745 INCHES MINIMUM AND 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM SECOND FLANGE0.755 INCHES MAXIMUM SECOND FLANGE IN
Flange Outside Height0.735 INCHES MINIMUM AND 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM FIRST FLANGE0.765 INCHES MAXIMUM FIRST FLANGE IN
Flange Connecting Hole Diameter0.116 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES0.116 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES IN
Waveguide Center to Center Distance1.275 FEET NOMINAL1.275 FEET NOMINAL FT
Flange Inside Width0.2786 INCHES MINIMUM AND 0.2786 INCHES MINIMUM AND 0.2814 INCHES MAXIMUM FIRST FLANGE0.2814 INCHES MAXIMUM FIRST FLANGE IN
Flange Inside Width0.360 INCHES MINIMUM AND 0.360 INCHES MINIMUM AND 0.362 INCHES MAXIMUM SECOND FLANGE0.362 INCHES MAXIMUM SECOND FLANGE IN
Waveguide Length1.373 FEET NOMINAL1.373 FEET NOMINAL FT
Waveguide Outside Height0.218 INCHES MINIMUM AND 0.218 INCHES MINIMUM AND 0.222 INCHES MAXIMUM0.222 INCHES MAXIMUM IN
Waveguide Outside Width0.358 INCHES MINIMUM AND 0.358 INCHES MINIMUM AND 0.362 INCHES MAXIMUM0.362 INCHES MAXIMUM IN
Flange Depth0.182 INCHES MINIMUM AND 0.182 INCHES MINIMUM AND 0.192 INCHES MAXIMUM SECOND FLANGE0.192 INCHES MAXIMUM SECOND FLANGE IN
Flange Depth0.195 INCHES MINIMUM AND 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM FIRST FLANGE0.225 INCHES MAXIMUM FIRST FLANGE IN
Flange Outside Width0.745 INCHES MINIMUM AND 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM SECOND FLANGE0.755 INCHES MAXIMUM SECOND FLANGE IN
Flange Outside Width0.735 INCHES MINIMUM AND 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM FIRST FLANGE0.765 INCHES MAXIMUM FIRST FLANGE IN
Insertion Loss in Decibels0.400.40
Surface TreatmentSILVER ALL FLANGE OUTSIDE SURFACES
Surface TreatmentENAMEL SINGLE TUBING SEGMENT OUTSIDE SURFACES
Waveguide Inside Height0.1385 INCHES MINIMUM AND 0.1385 INCHES MINIMUM AND 0.1415 INCHES MAXIMUM0.1415 INCHES MAXIMUM IN
MaterialSILVER ALLOY SINGLE TUBING SEGMENT
Flange Connecting Facility and Quantity4 UNTHREADED HOLE(S) FIRST FLANGE SINGLE CONNECTION FACILITY4 UNTHREADED HOLE(S) FIRST FLANGE SINGLE CONNECTION FACILITY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5330-01-568-159517-1-5849-1 POSSIBLE MATCH
GASKET
Possible match (shared part number)Nolato Jabar Llc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
17-15849-1 C/1 Advisory reference — outside the item-of-supply concept
Textron Systems Corporation Dba Textron Systems Corp
17-15849-1 3/9 Design control — primary reference
U.S. Government activity
Related Parts
5330-01-568-1595POSSIBLE MATCH
GASKET
17-1-5849-1

Frequently Asked Questions

What is NSN 5985-01-062-9420?

NSN 5985-01-062-9420 is a Waveguide Assembly, classified under FSC 5985, Antennas, Waveguides, and Related Equipment. Status: active.

What NSN replaces 5985-01-062-9420?

1 possible match (shared part number, not a government interchangeability claim): 5330-01-568-1595. Verify interchangeability with system specifications before substitution.

What are the specifications of 5985-01-062-9420?

Key specifications for 5985-01-062-9420: Tubing Wall Construction Style: SEAMLESS SINGLE TUBING SEGMENTSEAMLESS SINGLE TUBING SEGMENT; Flange Inside Height: 0.1386 INCHES MINIMUM AND 0.1386 INCHES MINIMUM AND 0.1414 INCHES MAXIMUM FIRST FLANGE0.1414 INCHES MAXIMUM FIRST FLANGE IN; Flange Inside Height: 0.220 INCHES MINIMUM AND 0.220 INCHES MINIMUM AND 0.224 INCHES MAXIMUM SECOND FLANGE0.224 INCHES MAXIMUM SECOND FLANGE IN; Flange Quantity: 22. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5985-01-062-9420 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com