The Waveguide Assembly, cataloged under National Stock Number 5985-00-461-3735, is classified within Federal Supply Class 5985 (Antennas, Waveguides, and Related Equipment) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5985-00-461-3735 |
| Item Name | Waveguide Assembly |
| FSC / FSG | 5985 / 59 — Antennas, Waveguides, and Related Equipment |
| Status | ACTIVE |
| FSC Application Data | ANTENNAS,WAVEGUIDES,AND RELTED EQUIPMENT |
| Tubing Wall Construction Style | SEAMLESS ALL TUBING SEGMENT |
| Flange Quantity | 2 |
| Bend Angle in Deg | 90.0 FIRST BEND E-PLANE |
| Bend Angle in Deg | 90.0 SECOND BEND H-PLANE |
| Style Designator | OFFSET BEND TYPE |
| Flexibility | RIGID ALL TUBING SEGMENT |
| Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| Waveguide Center to Center Distance | 3.270 INCHES NOMINAL IN |
| Waveguide Length | 2.110 INCHES NOMINAL IN |
| Tubing Twist Type | STRAIGHT TWIST FIRST TUBING SEGMENT |
| Tubing Twist Angle in Deg | 90.0 FIRST TUBING SEGMENT |
| Surface Treatment | CHROMATE AND ENAMEL AND PRIMER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| Material | METAL ALL TUBING SEGMENT AND FLANGE |
| Flange Style | COVER TYPE ALL FLANGES |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 675528-1 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5985-00-461-3735 is a Waveguide Assembly, classified under FSC 5985, Antennas, Waveguides, and Related Equipment. Status: active.
Key specifications for 5985-00-461-3735: FSC Application Data: ANTENNAS,WAVEGUIDES,AND RELTED EQUIPMENT; Tubing Wall Construction Style: SEAMLESS ALL TUBING SEGMENT; Flange Quantity: 2; Bend Angle in Deg: 90.0 FIRST BEND E-PLANE. 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.