PartsTable TECHNICAL DATA SHEET
NSN 5970-01-291-7495Government record, cited

Insulation Sleeving, Electrical, S5970-01-291-7495

NSN 5970-01-291-7495 · NIIN 012917495
FSC 5970 — Electrical Insulators and Insulating Materials · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5970-01-291-7495 · 5970012917495 · NIIN 012917495 · 01-291-7495 · FSC 5970 Electrical Insulators and Insulating Materials · 573H145-6-A · 573H145-6-A · 573H145-6-A · 573H145-6-A · 462A034-4/42
Nearby stock numbers  ·
Features
  • Insulation Sleeving,electrical,s — FSC 5970
  • Third Branch Inside Diameter: 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN
  • Third Branch Inside Diameter: 0.760 INCHES MINIMUM AS SUPPLIED IN
  • Distance From Intersecting Centerline of Main Body to End of First Branch: 2.900 INCHES NOMINAL AS SUPPLIED IN
  • Temp Rating: -55.0 CELSIUS DEGC
  • Second Branch Inside Diameter: 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN
  • Second Branch Inside Diameter: 0.760 INCHES MINIMUM AS SUPPLIED IN
  • Third Branch Wall Thickness: 0.070 INCHES NOMINAL AS SUPPLIED IN
Identification
  • NSN: 5970-01-291-7495
  • NIIN: 012917495
  • FSC: 5970 — Electrical Insulators and Insulating Materials
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Insulation Sleeving,electrical,s, cataloged under National Stock Number 5970-01-291-7495, is classified within Federal Supply Class 5970 (Electrical Insulators and Insulating Materials) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5970-01-291-7495
Item NameInsulation Sleeving,electrical,s
FSC / FSG5970 / 59 — Electrical Insulators and Insulating Materials
StatusACTIVE
Third Branch Inside Diameter0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN
Third Branch Inside Diameter0.760 INCHES MINIMUM AS SUPPLIED IN
Distance From Intersecting Centerline of Main Body to End of First Branch2.900 INCHES NOMINAL AS SUPPLIED IN
Temp Rating-55.0 CELSIUS DEGC
Second Branch Inside Diameter0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN
Second Branch Inside Diameter0.760 INCHES MINIMUM AS SUPPLIED IN
Third Branch Wall Thickness0.070 INCHES NOMINAL AS SUPPLIED IN
Angle Between Main Body and First Branch Centerlines in Deg10.0 NOMINAL AS SUPPLIED
Angle Between Main Body and First Branch Centerlines in Deg30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
Style DesignatorTRANSITION-1 TO 3 CABLES
FlexibilityFLEXIBLE
Material Document and ClassificationRT 1304,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
Second Branch Wall Thickness0.070 INCHES NOMINAL AS SUPPLIED IN
Main Body Inside Diameter0.740 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN
Main Body Inside Diameter1.520 INCHES MINIMUM AS SUPPLIED IN
Main Body Overall Length5.320 INCHES NOMINAL AS SUPPLIED IN
Distance From Edge of Main Body to Intersecting Centerlines2.420 INCHES NOMINAL AS SUPPLIED IN
First Branch Wall Thickness0.070 INCHES NOMINAL AS SUPPLIED IN
ColorBLACK
Environmental ProtectionCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
Minimum Tensile Strength1200 POUNDS PER SQUARE INCH LBS
MaterialPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
First Branch Inside Diameter0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN
First Branch Inside Diameter0.760 INCHES MINIMUM AS SUPPLIED IN
Main Body Wall Thickness0.120 INCHES NOMINAL AS SUPPLIED IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
573H145-6-A C/1 Advisory reference — outside the item-of-supply concept
3m Company Dba 3m
573H145-6-A 5/9 Secondary reference
3m Co Admininistrative Electronic & Communications
573H145-6-A 5/9 Secondary reference
Minnesota Mining and Mfg Co
573H145-6-A 5/9 Secondary reference
Minnesota Mining and Mfg Co 3m Company
462A034-4/42 5/9 Secondary reference
Te Connectivity Corporation Dba Raychem Product Division
6259291-6 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5970 — Electrical Insulators and Insulating Materials
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5970-00-001-1330
5970-00-001-1330 · Item name not on file
5970-00-001-1357
INSULATOR,BUSHING
5970-00-001-1418
INSULATOR,BUSHING
5970-00-001-1420
INSULATOR,PLATE
5970-00-001-1472
INSULATOR,PLATE
5970-00-001-1476
INSULATOR,WASHER
5970-00-001-1477
5970-00-001-1477 · Item name not on file
5970-00-001-1479
5970-00-001-1479 · Item name not on file

Frequently Asked Questions

What is NSN 5970-01-291-7495?

NSN 5970-01-291-7495 is a Insulation Sleeving,electrical,s, classified under FSC 5970, Electrical Insulators and Insulating Materials. Status: active.

What are the specifications of 5970-01-291-7495?

Key specifications for 5970-01-291-7495: Third Branch Inside Diameter: 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN; Third Branch Inside Diameter: 0.760 INCHES MINIMUM AS SUPPLIED IN; Distance From Intersecting Centerline of Main Body to End of First Branch: 2.900 INCHES NOMINAL AS SUPPLIED IN; Temp Rating: -55.0 CELSIUS DEGC. 25 specifications are documented in the U.S. Government catalog.

Is NSN 5970-01-291-7495 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com