The Insulation Sleeving,electrical,s, cataloged under National Stock Number 5970-01-147-7209, is classified within Federal Supply Class 5970 (Electrical Insulators and Insulating Materials) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5970-01-147-7209 |
| Item Name | Insulation Sleeving,electrical,s |
| FSC / FSG | 5970 / 59 — Electrical Insulators and Insulating Materials |
| Status | ACTIVE |
| Main Body Small End Inside Diameter | 0.220 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| Main Body Small End Inside Diameter | 0.920 INCHES MINIMUM AS SUPPLIED IN |
| Temp Rating | -55.0 CELSIUS AND 125.0 CELSIUS DEGC |
| Distance From Top of Shoulder to Small End of Main Body | 0.400 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Main Body Large End Inside Diameter | 0.410 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| Main Body Large End Inside Diameter | 0.920 INCHES MINIMUM AS SUPPLIED IN |
| Style Designator | BOOT-STRAIGHT |
| Flexibility | SEMIRIGID |
| Material Document and Classification | RT-301,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE OR MPP-262,3M CO MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED |
| Main Body Overall Length | 1.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Dielectric Material Voltage Rating Per Unit Thickness | 200.0 VOLTS PER MIL /0.001 INCH/ IN |
| Color | BLACK |
| Environmental Protection | FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
| Distance From Bottom of Shoulder to Large End of Main Body | 0.830 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Minimum Tensile Strength | 1500 POUNDS PER SQUARE INCH LBS |
| Material | PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED |
| Main Body Wall Thickness | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 313D232-3-M-250 | 5/9 Secondary reference 3m Co Admininistrative Electronic & Communications |
| GB806M1-3-00-42 | 5/9 Secondary reference Northrop Grumman Systems Corporation |
| 202D121-3-00/42 | 3/9 Design control — primary reference Te Connectivity Corporation Dba Raychem Product Division |
| 313D263-1MP-AL | 5/9 Secondary reference 3m Co Admininistrative Electronic & Communications |
NSN 5970-01-147-7209 is a Insulation Sleeving,electrical,s, classified under FSC 5970, Electrical Insulators and Insulating Materials. Status: active.
Key specifications for 5970-01-147-7209: Main Body Small End Inside Diameter: 0.220 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN; Main Body Small End Inside Diameter: 0.920 INCHES MINIMUM AS SUPPLIED IN; Temp Rating: -55.0 CELSIUS AND 125.0 CELSIUS DEGC; Distance From Top of Shoulder to Small End of Main Body: 0.400 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN. 17 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.