The Insulation Sleeving,electrical,s, cataloged under National Stock Number 5970-01-090-2517, is classified within Federal Supply Class 5970 (Electrical Insulators and Insulating Materials) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5970-01-090-2517 |
| Item Name | Insulation Sleeving,electrical,s |
| FSC / FSG | 5970 / 59 — Electrical Insulators and Insulating Materials |
| Status | ACTIVE |
| Temp Rating | -55.0 CELSIUS DEGC |
| Angle Between Main Body and First Branch Centerlines in Deg | 90.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| Angle Between Main Body and First Branch Centerlines in Deg | 165.0 NOMINAL AS SUPPLIED |
| Style Designator | TRANSITION-T |
| Flexibility | FLEXIBLE |
| Distance From Centerline of Main Body to End of First Branch | 0.930 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Main Body Inside Diameter | 0.700 INCHES MINIMUM AS SUPPLIED IN |
| Main Body Inside Diameter | 0.350 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| Main Body Overall Length | 1.870 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Dielectric Material Voltage Rating Per Unit Thickness | 200.0 VOLTS PER MIL /0.001 INCH/ IN |
| First Branch Wall Thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Color | BLACK |
| Environmental Protection | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
| Minimum Tensile Strength | 1200 POUNDS PER SQUARE INCH LBS |
| Material | PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED |
| First Branch Inside Diameter | 0.400 INCHES MINIMUM AS SUPPLIED IN |
| First Branch Inside Diameter | 0.200 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| Main Body Wall Thickness | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 433H523-6 | 5/9 Secondary reference 3m Company |
| 433H523-6 | 5/9 Secondary reference 3m Co Admininistrative Electronic & Communications |
| 322A412-4 | 5/9 Secondary reference Te Connectivity Corporation Dba Raychem Product Division |
| 202-25201FP10 | 5/1 Secondary reference U.S. Government activity |
| 433H523-6 | 3/9 Design control — primary reference 3m Company Dba 3m |
| 433H523-6 | 5/9 Secondary reference Minnesota Mining and Mfg Co |
NSN 5970-01-090-2517 is a Insulation Sleeving,electrical,s, classified under FSC 5970, Electrical Insulators and Insulating Materials. Status: active.
Key specifications for 5970-01-090-2517: Temp Rating: -55.0 CELSIUS DEGC; Angle Between Main Body and First Branch Centerlines in Deg: 90.0 NOMINAL AFTER UNRESTRICTED RECOVERY; Angle Between Main Body and First Branch Centerlines in Deg: 165.0 NOMINAL AS SUPPLIED; Style Designator: TRANSITION-T. 18 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.