PartsTable TECHNICAL DATA SHEET
NSN 5962-01-491-9504Government record, cited

Microcircuit, Linear5962-01-491-9504

NSN 5962-01-491-9504 · NIIN 014919504
FSC 5962 — Microcircuits, Electronic · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5962-01-491-9504 · 5962014919504 · NIIN 014919504 · 01-491-9504 · FSC 5962 Microcircuits, Electronic · 0N634275-1 · MAX792LCSE · MAX792LCSE
Nearby stock numbers  ·
Features
  • Microcircuit,linear — FSC 5962
  • Inclosure Material: PLASTIC
  • Terminal Surface Treatment: SOLDER
  • Design Function and Quantity: 4 MONITOR, VOLTAGE AND 1 MICROPROCESSOR
  • Inclosure Configuration: DUAL-IN-LINE
  • Storage Temp Range: -65.0 TO 150.0 CELSIUS DEGC
  • Voltage Rating and Type Per Characteristic: -0.3 VOLTS MINIMUM INPUT AND 6.0 VOLTS MAXIMUM INPUT
  • Operating Temp Range: +0.0 TO 70.0 CELSIUS DEGC
Identification
  • NSN: 5962-01-491-9504
  • NIIN: 014919504
  • FSC: 5962 — Microcircuits, Electronic
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Microcircuit,linear, cataloged under National Stock Number 5962-01-491-9504, is classified within Federal Supply Class 5962 (Microcircuits, Electronic) of the Electrical and Electronic Equipment Components group. Government technical data includes 9 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5962-01-491-9504
Item NameMicrocircuit,linear
FSC / FSG5962 / 59 — Microcircuits, Electronic
StatusACTIVE
Inclosure MaterialPLASTIC
Terminal Surface TreatmentSOLDER
Design Function and Quantity4 MONITOR, VOLTAGE AND 1 MICROPROCESSOR
Inclosure ConfigurationDUAL-IN-LINE
Storage Temp Range-65.0 TO 150.0 CELSIUS DEGC
Voltage Rating and Type Per Characteristic-0.3 VOLTS MINIMUM INPUT AND 6.0 VOLTS MAXIMUM INPUT
Operating Temp Range+0.0 TO 70.0 CELSIUS DEGC
Terminal Type and Quantity16 GULLWING
Maximum Power Dissipation Rating762.0 MILLIWATTS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL B — Remove Demilitarization Key Points
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5962-01-496-5287MAX792LCSE POSSIBLE MATCH
MICROCIRCUIT,LINEAR
Possible match (shared part number)Maxim Technologies Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
0N634275-1 7/2 Vendor item drawing reference
U.S. Government activity
MAX792LCSE 5/9 Secondary reference
U.S. Government activity
MAX792LCSE 3/9 Design control — primary reference
Maxim Integrated Products, Inc.
Related Parts
5962-01-496-5287POSSIBLE MATCH
MICROCIRCUIT,LINEAR
MAX792LCSE

Frequently Asked Questions

What is NSN 5962-01-491-9504?

NSN 5962-01-491-9504 is a Microcircuit,linear, classified under FSC 5962, Microcircuits, Electronic. Status: active.

What NSN replaces 5962-01-491-9504?

1 possible match (shared part number, not a government interchangeability claim): 5962-01-496-5287. Verify interchangeability with system specifications before substitution.

What are the specifications of 5962-01-491-9504?

Key specifications for 5962-01-491-9504: Overall Height: 0.053 INCHES MINIMUM AND 0.069 INCHES MAXIMUM IN; Inclosure Material: PLASTIC; Terminal Surface Treatment: SOLDER; Design Function and Quantity: 4 MONITOR, VOLTAGE AND 1 MICROPROCESSOR. 9 specifications are documented in the U.S. Government catalog.

Is NSN 5962-01-491-9504 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5962-01-491-9504?

NSN 5962-01-491-9504 has DEMIL Code B. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com